==2023.09.01: Product technical changes==
 +
 +
Starting from 2023 Q3 BAT120 Uninterruptable Power Supply will be changed.
 +
 +
{| class="wikitable"
 +
|+
 +
! style="text-align: left; background: white;" colspan="3" | Change description
 +
|-
 +
| style="text-align: left; background: white;" | Change type
 +
| style="text-align: left; background: white;" colspan="2" | LED Indicators, Faster Charging
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" | Detailed description
 +
| style="width: 908px; text-align: left; background: white;" | The updated BAT120 will has several updated specifications, including enhancements to the LED indicators and an increase in battery charge current, resulting in improved charging for the device.
 +
 +
The LED indicators will now provide updated information:
 +
*IN PWR LED (Green): When the PSU is connected to the IN PWR socket, the LED will turn green, indicating that the battery is actively charging.
 +
*IN PWR LED (Red): If the PSU is connected to the IN PWR socket but there is a charge failure or the input voltage (Vin) is too low, the LED will turn red, alerting you to the issue.
 +
*OUT PWR LED (Green): When an external device is being powered through the OUT PWR socket, the LED will illuminate in green, ensuring you know that the output power is available.
 +
*OUT PWR LED (Red): If the OUTPUT is shorted (requiring a reset) or the BAT120 has overheated (no reset needed), the OUT PWR LED will turn red, signifying an issue that needs attention.
 +
*POWER LEDs (Blinking every 5 seconds): We have implemented a state-of-charge indicator for the battery. The POWER LEDs will now blink every 5 seconds, with each LED representing 25% of the battery's charge.
 +
|-
 +
| style="text-align: left; background: white;" | Change reasons
 +
| style="text-align: left; background: white;" | Improved LED indicators and enhanced battery charging for better user experience
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! style="text-align: left; background: white;" colspan="3" | Affected products information
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" | Model
 +
| style="width: 448px; text-align: left; background: white;" | Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" | BAT120
 +
| style="text-align: left; background: white;" | BAT120 *****
 +
| style="text-align: left; background: white;" | No changes
 +
|-
 +
| style="text-align: left; background: white;" | Upcoming change date
 +
| style="text-align: left; background: white;" colspan="2" | 2023 Q3
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! style="text-align: left; background: white;" colspan="3" | Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" | Risk assessment
 +
| style="width: 908px; text-align: left; background: white;" colspan="2"| The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
 +
|-
 +
| style="text-align: left; background: white;" | Suggested implementation plan
 +
| style="text-align: left; background: white;" colspan="2"| Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
 +
|-
 +
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
 +
 +
To download the pdf version of this notification, [[Media:PCN_BAT120_2023_09_01_EN_TECHNICAL CHANGES.pdf|click here]].
    
==2023.05.24: QSG flyer replacement==
 
==2023.05.24: QSG flyer replacement==