TSW030 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.23
Idle (12 V)
20
0.24
Idle (24 V)
11
0.26
Idle (44 V)
11
0.31
Idle (50 V)
6
0.3
Idle (57 V)
6
0.34


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
49
0.45
2 LAN devices connected + heavy data traffic1 (12 V)
39
0.47
2 LAN devices connected + heavy data traffic1 (24 V)
24
0.58


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
78
0.70
5 LAN devices connected + heavy data traffic1 (12 V)
61
0.73
5 LAN devices connected + heavy data traffic1 (24 V)
37
0.89


1 - Data streams between devices were created using iPerf.