RUT300 Product Change Notifications

Main Page > RUT Routers > RUT300 > RUT300 Product Change Notifications

Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).

This page stores information regarding changes to the RUT300 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).

2024.03.08: Reset button functionality change RutOS 7.07

With the release of RutOS version 7.07, RUT300 device will experience changes related to the security improvements of the device.

PCN Number: PCN_RUTOS_CHANGE_2024_03_08_EN
Change description
Change type Firmware change
Detailed description Previously, during device resets, logs and RMS connection state data remained unchanged. However, starting with RutOS firmware version 7.07, all devices will uniformly reset logs and RMS connection state data to factory defaults when using the reset button. Other reset methods will remain unimpacted by this change.
Change reasons Increasing security
Affected products information
Model Affected order codes Order code changes
RUT300 RUT300 ***** No changes
Upcoming change date 2024 Q2, with the release of RutOS 7.07
Change impact
Risk assessment
  • The loss of device logs upon utilizing the reset button may disrupt operational records and slow down subsequent troubleshooting efforts.
  • The device is still visible in RMS post-reset but cannot be accessed. Therefore, re-adding the device to RMS is necessary for continued access.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2023.10.17: Product packaging changes

Starting from December 2023 RUT300 product packaging will be changed.

Change description
Change type Packaging
Detailed description Starting from December 2023 RUT300 plastic bubble bag will be replaced by honeycomb insert made from cardboard.
Current packaging:

Plastic bubble bag v1.jpg
Updated packaging:

Insert Carton NEW 06.04.23.png
Packaging dimensions will not change.
Change reasons This change will improve structural stability, enhance impact resistance, and reduce environmental impact.
Affected products information
Model Current order code New order code
RUT300 RUT300 ****** No changes
Upcoming change date December 2023
Change impact
Risk assessment The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2023.02.13: MAC address range change

All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.

Change description
Change type MAC address range
Detailed description All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons Endpoint of the previous MAC address range.
Affected products information
Model Affected order codes Order code changes
All Teltonika Networks devices All order codes No changes
Upcoming change date 2023, week 9
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2022.11.25: Default password change

All RUT300 devices manufactured starting from 2022, week 50, will have unique default password.

Change description
Change type Default password change.
Detailed description RUT300 devices manufactured starting from Q4 2022 will have unique default password.
Change reasons Increasing device security.
Affected products information
Model Affected order codes Order code changes
RUT300 RUT300 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications. Please note: this product change notification does not affect any previous RUT300 devices.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.


2022.11.25: QSG flyer replacement

Starting from 2022, week 50, RUT300 routers will come with a new QSG flyer in the packaging.

Change description
Change type Replacement of QSG flyer
Detailed description RUT300 devices manufactured starting from Q4 2022 will have a new QSG flyer in the packaging. The new QSG flyer includes the short version of QSG with a QR code/link to the full Web QSG version: teltonika-networks.com/QSG_RUT300
Previous design:
QSG RUT300 EN old.png
New design:
QSG RUT300 EN new.png
The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the RUT300.
Change reasons Reducing environmental impact.
Affected products information
Model Affected order codes Order code changes
RUT300 RUT300 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2022.11.25: Changes in engraving/labeling

Starting from 2022, week 50, RUT300 routers will be produced with modified bottom engraving/labeling.

Change description
Change type External/visual
Detailed description The device's unique default password will be added to the bottom engraving/labeling. The formatting for the remaining information on the labeling/engraving will be adjusted, and the Fira font will be used instead of Arial. The device's unique default password information will also be added to the QR code Information displayed after scanning QR code with syntax: SN:{{SN}};M:{{MAC}};U:admin;PW:{{DEVICEPASSWORD}};B:{{BATCH}};


From the device top engraving/labeling, the previously relevant authentication information text will be removed: User/Pass: admin/admin01.


The labeling on the product packaging will stay unchanged.

Old top engraving/labeling:
RUT300 hd 1.png

Old bottom engraving/labeling:

600px-Networking RUT300 first start gaminio lipdukas v3.png
New top engraving/labeling:
RUT300 hd 4 new top.png

New bottom engraving/labeling:

RUT300 LanMAC.png
Change reasons To accommodate the change from the standard default password to a unique default password for each device.
Affected products information
Model Affected order codes Order code changes
RUT300 RUT300 ****** No changes
Upcoming change date 2022, week 50
Change impact
Risk assessment Changes to top labeling/engraving. Device's unique default password will be present on the product itself. This might impact marketing materials due to changing contents of the bottom informational engraving/labeling.
Suggested implementation plan No implementation plan needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.