Difference between revisions of "Template:Networking tsw100 faq power consumption table"

From Teltonika Networks Wiki
m (Protected "Template:Networking tsw100 faq power consumption table" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
Line 1: Line 1:
 
<table class="nd-othertables_3">
 
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (12 V)</td>
 +
      <td><b>26</b></td>
 +
      <td><b>0.31</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (24 V)</td>
 +
      <td><b>20</b></td>
 +
      <td><b>0.48</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (44 V)</td>
 +
      <td><b>15</b></td>
 +
      <td><b>0.64</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (50 V)</td>
 +
      <td><b>14</b></td>
 +
      <td><b>0.70</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (57 V)</td>
 +
      <td><b>13</b></td>
 +
      <td><b>0.77</b></td>
 +
    </tr>
 +
</table>
 +
 +
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (12 V)</td>
 +
      <td><b>148</b></td>
 +
      <td><b>1.82</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (24 V)</td>
 +
      <td><b>82</b></td>
 +
      <td><b>1.93</b></td>
 +
    </tr>
 
     <tr>
 
     <tr>
         <th width=250>State</th>
+
        <td>5 LAN devices connected + heavy data traffic (44 V)</td>
      <th width=200>Average power (W)</th>
+
      <td><b>52</b></td>
       <th width=100>Peak power (W)</th>
+
      <td><b>2.31</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (50 V)</td>
 +
      <td><b>48</b></td>
 +
      <td><b>2.40</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (57 V)</td>
 +
      <td><b>44</b></td>
 +
      <td><b>2.50</b></td>
 +
    </tr>
 +
</table>
 +
 
 +
 
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
         <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
       <th width=150>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Idle</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (44 V)</td>
        <td>0.457</td>
+
      <td><b>444</b></td>
        <td>1.311</td>
+
      <td><b>19.54</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>PoE devices connected</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (50 V)</td>
        <td>27.517<span class="asterisk">*</span></td>
+
      <td><b>388</b></td>
        <td>37.448<span class="asterisk">*</span></td>
+
      <td><b>19.40</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Heavy data traffic</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (57 V)</td>
        <td>2.033</td>
+
      <td><b>343</b></td>
        <td>8.4</td>
+
      <td><b>19.55</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
  
<font size="-1"><span class="asterisk">*</span>Capable of up to 102 W; depends on power supply.</font>
+
 
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (44 V)</td>
 +
      <td><b>1789</b></td>
 +
      <td><b>78.72</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (50 V)</td>
 +
      <td><b>2050</b></td>
 +
      <td><b>102.50</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (57 V)</td>
 +
      <td><b>2344</b></td>
 +
      <td><b>133.61</b></td>
 +
    </tr>
 +
</table>

Revision as of 14:00, 18 February 2022

Test type Current (mA) Power consumption (W)
Idle (12 V) 26 0.31
Idle (24 V) 20 0.48
Idle (44 V) 15 0.64
Idle (50 V) 14 0.70
Idle (57 V) 13 0.77


Test type Current (mA) Power consumption (W)
5 LAN devices connected + heavy data traffic (12 V) 148 1.82
5 LAN devices connected + heavy data traffic (24 V) 82 1.93
5 LAN devices connected + heavy data traffic (44 V) 52 2.31
5 LAN devices connected + heavy data traffic (50 V) 48 2.40
5 LAN devices connected + heavy data traffic (57 V) 44 2.50


Test type Current (mA) Power consumption (W)
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (44 V) 444 19.54
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (50 V) 388 19.40
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (57 V) 343 19.55


Test type Current (mA) Power consumption (W)
4 PoE dummy loads connected (30 W each) (44 V) 1789 78.72
4 PoE dummy loads connected (30 W each) (50 V) 2050 102.50
4 PoE dummy loads connected (30 W each) (57 V) 2344 133.61