Template:Networking tsw100 faq power consumption table

From Teltonika Networks Wiki
Test type
Current (mA)
Power consumption (W)
Idle (12 V)
26
0.31
Idle (24 V)
20
0.48
Idle (44 V)
15
0.64
Idle (50 V)
14
0.70
Idle (57 V)
13
0.77


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (12 V)
148
1.82
5 LAN devices connected + heavy data traffic1 (24 V)
82
1.93
5 LAN devices connected + heavy data traffic1 (44 V)
52
2.31
5 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
5 LAN devices connected + heavy data traffic1 (57 V)
44
2.50


Test type
Current (mA)
Power consumption (W)
4 PoE devices connected + heavy data traffic1 (44 V)
444
19.54
4 PoE devices connected + heavy data traffic1 (50 V)
388
19.40
4 PoE devices connected + heavy data traffic1 (57 V)
343
19.55


Test type
Current (mA)
Power consumption (W)
4 PoE dummy loads connected (30 W each) (44 V)
1789
78.72
4 PoE dummy loads connected (30 W each) (50 V)
2050
102.50
4 PoE dummy loads connected (30 W each) (57 V)
2344
133.61


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.