Difference between revisions of "Template:Networking tsw100 faq power consumption table"

From Teltonika Networks Wiki
Line 2: Line 2:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle (12 V)</td>
 
         <td>Idle (12 V)</td>
       <td><b>26</b></td>
+
       <td><center><b>26</b></td>
       <td><b>0.31</b></td>
+
       <td><center><b>0.31</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle (24 V)</td>
 
         <td>Idle (24 V)</td>
       <td><b>20</b></td>
+
       <td><center><b>20</b></td>
       <td><b>0.48</b></td>
+
       <td><center><b>0.48</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle (44 V)</td>
 
         <td>Idle (44 V)</td>
       <td><b>15</b></td>
+
       <td><center><b>15</b></td>
       <td><b>0.64</b></td>
+
       <td><center><b>0.64</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle (50 V)</td>
 
         <td>Idle (50 V)</td>
       <td><b>14</b></td>
+
       <td><center><b>14</b></td>
       <td><b>0.70</b></td>
+
       <td><center><b>0.70</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle (57 V)</td>
 
         <td>Idle (57 V)</td>
       <td><b>13</b></td>
+
       <td><center><b>13</b></td>
       <td><b>0.77</b></td>
+
       <td><center><b>0.77</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 36: Line 36:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td>
       <td><b>148</b></td>
+
       <td><center><b>148</b></td>
       <td><b>1.82</b></td>
+
       <td><center><b>1.82</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td>
       <td><b>82</b></td>
+
       <td><center><b>82</b></td>
       <td><b>1.93</b></td>
+
       <td><center><b>1.93</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
       <td><b>52</b></td>
+
       <td><center><b>52</b></td>
       <td><b>2.31</b></td>
+
       <td><center><b>2.31</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (50 V)</td>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (50 V)</td>
       <td><b>48</b></td>
+
       <td><center><b>48</b></td>
       <td><b>2.40</b></td>
+
       <td><center><b>2.40</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
 
         <td>5 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
       <td><b>44</b></td>
+
       <td><center><b>44</b></td>
       <td><b>2.50</b></td>
+
       <td><center><b>2.50</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 70: Line 70:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
       <td><b>444</b></td>
+
       <td><center><b>444</b></td>
       <td><b>19.54</b></td>
+
       <td><center><b>19.54</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (50 V)</td>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (50 V)</td>
       <td><b>388</b></td>
+
       <td><center><b>388</b></td>
       <td><b>19.40</b></td>
+
       <td><center><b>19.40</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
 
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
       <td><b>343</b></td>
+
       <td><center><b>343</b></td>
       <td><b>19.55</b></td>
+
       <td><center><b>19.55</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 94: Line 94:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE dummy loads connected (30 W each) (44 V)</td>
 
         <td>4 PoE dummy loads connected (30 W each) (44 V)</td>
       <td><b>1789</b></td>
+
       <td><center><b>1789</b></td>
       <td><b>78.72</b></td>
+
       <td><center><b>78.72</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE dummy loads connected (30 W each) (50 V)</td>
 
         <td>4 PoE dummy loads connected (30 W each) (50 V)</td>
       <td><b>2050</b></td>
+
       <td><center><b>2050</b></td>
       <td><b>102.50</b></td>
+
       <td><center><b>102.50</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>4 PoE dummy loads connected (30 W each) (57 V)</td>
 
         <td>4 PoE dummy loads connected (30 W each) (57 V)</td>
       <td><b>2344</b></td>
+
       <td><center><b>2344</b></td>
       <td><b>133.61</b></td>
+
       <td><center><b>133.61</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
 +
  
 
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br>
 
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br>
 
<small>Power consumption may differ due to connected devices, testing environment and conditions.</small>
 
<small>Power consumption may differ due to connected devices, testing environment and conditions.</small>

Revision as of 15:41, 7 June 2022

Test type
Current (mA)
Power consumption (W)
Idle (12 V)
26
0.31
Idle (24 V)
20
0.48
Idle (44 V)
15
0.64
Idle (50 V)
14
0.70
Idle (57 V)
13
0.77


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (12 V)
148
1.82
5 LAN devices connected + heavy data traffic1 (24 V)
82
1.93
5 LAN devices connected + heavy data traffic1 (44 V)
52
2.31
5 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
5 LAN devices connected + heavy data traffic1 (57 V)
44
2.50


Test type
Current (mA)
Power consumption (W)
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (44 V)
444
19.54
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (50 V)
388
19.40
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (57 V)
343
19.55


Test type
Current (mA)
Power consumption (W)
4 PoE dummy loads connected (30 W each) (44 V)
1789
78.72
4 PoE dummy loads connected (30 W each) (50 V)
2050
102.50
4 PoE dummy loads connected (30 W each) (57 V)
2344
133.61


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.