Test type Current (mA) Power consumption (W)
Idle (12 V) 26 0.31
Idle (24 V) 20 0.48
Idle (44 V) 15 0.64
Idle (50 V) 14 0.70
Idle (57 V) 13 0.77


Test type Current (mA) Power consumption (W)
5 LAN devices connected + heavy data traffic (12 V) 148 1.82
5 LAN devices connected + heavy data traffic (24 V) 82 1.93
5 LAN devices connected + heavy data traffic (44 V) 52 2.31
5 LAN devices connected + heavy data traffic (50 V) 48 2.40
5 LAN devices connected + heavy data traffic (57 V) 44 2.50


Test type Current (mA) Power consumption (W)
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (44 V) 444 19.54
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (50 V) 388 19.40
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (57 V) 343 19.55


Test type Current (mA) Power consumption (W)
4 PoE dummy loads connected (30 W each) (44 V) 1789 78.72
4 PoE dummy loads connected (30 W each) (50 V) 2050 102.50
4 PoE dummy loads connected (30 W each) (57 V) 2344 133.61