Test type Current (mA) Power consumption (W)
Idle (12 V) 26 0.31
Idle (24 V) 20 0.48
Idle (44 V) 15 0.64
Idle (50 V) 14 0.70
Idle (57 V) 13 0.77


Test type Current (mA) Power consumption (W)
5 LAN devices connected + heavy data traffic1 (12 V) 148 1.82
5 LAN devices connected + heavy data traffic1 (24 V) 82 1.93
5 LAN devices connected + heavy data traffic1 (44 V) 52 2.31
5 LAN devices connected + heavy data traffic1 (50 V) 48 2.40
5 LAN devices connected + heavy data traffic1 (57 V) 44 2.50


Test type Current (mA) Power consumption (W)
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (44 V) 444 19.54
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (50 V) 388 19.40
4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic1 (57 V) 343 19.55


Test type Current (mA) Power consumption (W)
4 PoE dummy loads connected (30 W each) (44 V) 1789 78.72
4 PoE dummy loads connected (30 W each) (50 V) 2050 102.50
4 PoE dummy loads connected (30 W each) (57 V) 2344 133.61

1 - Data streams between devices were created using iPerf.