Latest revision as of 13:58, 9 January 2019
field name | value | description |
---|---|---|
Direct connect | ip:port | host:port; Default: none | Maintains a constant connection to the specified host. Leave empty if you are planning to use an ATD command to initiate the connection |
TCP port | integer [0..65535]; Default: none | Internal TCP port number used to listen for incoming connections. Leave it empty to disable incoming connections |
Initiation string* | string; Default: none | A command string that will be sent to the modem to initiate the connection in some particular way (optional) |
No extra CR LF in response | yes | no; Default: no | Removes extra CR LF before response code; removes LF after response code |
* This is the AT command set used in Modem mode of the serial interfaces:
command | description | usage |
---|---|---|
A | Answers an incoming call | To answer incoming connection: ATA |
D | Dials a number | To initiate data connection: ATD <HOST>:<PORT> To enter data mode with Direct connect settings: ATD |
E | Local echo | Turn local echo ON: ATE1 Turn local echo OFF: ATE0 |
H | Hang up current call | To end data connection: ATH |
O | Return to data mode | To return to data mode from command mode: ATO |
Z | Reset to default configuration | To reset the modem to default configuration: ATZ |