QSG SWM281
This Wiki page contains the online version of the Quick Start Guide (QSG) for the SWM281 managed switch . Here you will find an overview of the various components on the front and back of a SWM281 device, hardware installation instructions, first login information, device specifications, and general safety information. It is highly recommended to acquaint yourself with the Quick Start Guide before using the device. You can also locate a printed version of the Quick Start Guide in the packaging box of your device.
Safety information
Before starting operating the device, please review recommendations and precautions to minimize the possibility of accidents. Safety precautions presented are supplementary and subject to the local safety regulations. When various operations are executed on the device, the user must fully follow the safety instructions and recommendations provided with the device.
General
| Technical specifications | |
|---|---|
| Input voltage range | 100-240 VAC 50/60 Hz |
| Max power consumption | 20 W |
| Bundled accessories specifications** | |
| Power adapter | No accessories |
** Order code dependant.
Quick Start Guide
Front view

Back view

Connectors
POWER SOCKET PINOUT

RJ45 LED MEANING

SFP LED MEANING

Hardware installation
![]() |
![]() |
![]() |
Login to device (PROFINET Disabled)
Windows - Teltonika Profinet Configurator
This guide walks you through installing and using the Teltonika PROFINET Configurator on Windows 11 to set up the switch. Once a valid IP address and subnet mask are assigned, the WebUI becomes accessible.
▶️ Click to expand details
Teltonika PROFINET Configurator Setup on Windows 11
This tutorial explains how to install and use the Teltonika PROFINET Configurator on Windows 11 to configure the SWM280 switch.
After assigning a suitable IP address and subnet mask, the WebUI of the SWM280 can be reached.
The SWM280 version with enabled PROFINET comes with the following factory settings:
- IP Address 0.0.0.0
- Netmask 255.255.255.0
- Gateway 0.0.0.0
Requirements
- Windows 11 PC
- SWM280
- Network cable connected from the PC to the SWM280 device
- Teltonika PROFINET Configurator installer
Step 1: Download the Installer
- Download the installer from this wiki page and locate it in your Downloads folder.
- Double-click the installer file and follow the setup wizard.
Press Next to continue.
Step 2: Complete Installation
When installation finishes, leave the checkboxes ticked to run the Configurator and create a desktop shortcut.
Step 3: Install WinPcap
The PROFINET Configurator requires WinPcap for network scanning. If prompted, install it by following the wizard.
Step 4: Run with Administrator Rights
When first launched, the Configurator may show an error that admin privileges are required.
Close the application, right-click the desktop shortcut, and select Run as administrator.
Step 5: Application Interface
After launching with admin rights, the application will open successfully.
ℹ️ The images show TSW202 because its interface and configuration process are identical to other PROFINET-supported devices, including the one used in this tutorial. This makes the instructions fully applicable across models.
Step 6: Select Network Interface
From the drop-down list, select the correct network adapter connected to the SWM280, then press Start Scan.
Step 7: Configure SWM280
The connected device (SWM280) will appear in the list.
Click Configure to assign the name, IP address, netmask, and gateway.
Enter the desired configuration and press Save & Apply.
Step 8: Confirm Device Configuration
After saving, a confirmation message will appear.
The SWM280 will now be listed with its new IP configuration.
Step 9: Access the WebUI
Open a browser and enter the assigned IP address (e.g., 192.168.1.2). The SWM280 WebUI login screen will appear.
Log in using your SWM280 device credentials. You will find the username and password are located on your device.
Linux (Ubuntu) - Teltonika Profinet Configurator
This guide walks you through installing and using the Teltonika PROFINET Configurator on Linux (Ubuntu) to set up the switch. Once a valid IP address and subnet mask are assigned, the WebUI becomes accessible.
▶️ Click to expand details
Teltonika PROFINET Configurator Setup on Linux (Ubuntu)
This tutorial explains how to install and use the Teltonika PROFINET Configurator on Linux (Ubuntu) configure the SWM280 switch.
After assigning a suitable IP address and subnet mask, the WebUI of the SWM280 can be reached.
The SWM280 version with enabled PROFINET comes with the following factory settings:
- IP Address 0.0.0.0
- Netmask 255.255.255.0
- Gateway 0.0.0.0
Requirements
- Linux (Ubuntu 22.04) PC
- SWM280
- Network cable connected from the PC to the SWM280 device
- Click Save as - Download Teltonika PROFINET Configurator installer
Step 1: Download the application
- Download the application from this wiki page and locate it in your Downloads folder.
- AppImage is a universal way of running aplications on most of the Linux distributions, but it requires a few additional steps before you can run it.
Step 2: Make the AppImage Executable
Before running the application on Ubuntu, the AppImage file must be given execution permission.
Open a terminal in the folder where the file is located and enter:
chmod +x Teltonika\ PROFINET\ Configurator_0.1.0_amd64.AppImage
Step 3: Run the AppImage
The application must be executed with administrator sudo rights, because it requires elevated permissions for network scanning and device detection.
Requirement: Linux (Ubuntu 22.04) PC
Use the following command to run it:
sudo ./Teltonika\ PROFINET\ Configurator_0.1.0_amd64.AppImage
If you encounter an error such as **dlopen(): error loading libfuse.so.2**, it means that the required FUSE library is missing.
To fix it, install the necessary package using:
sudo apt update sudo apt install libfuse2
After installing, run the AppImage again with sudo:
sudo ./Teltonika\ PROFINET\ Configurator_0.1.0_amd64.AppImage
Step 4: Application Interface
After launching with admin rights, the application will open successfully.
ℹ️ The images show TSW202 because its interface and configuration process are identical to other PROFINET-supported devices, including the one used in this tutorial. This makes the instructions fully applicable across models.
Step 6: Select Network Interface
From the drop-down list, select the correct network adapter connected to the SWM280, then press Start Scan.
Step 7: Configure SWM280
The connected device (SWM280) will appear in the list.
Click Configure to assign the name, IP address, netmask, and gateway.
Enter the desired configuration and press Save & Apply.
Step 8: Confirm Device Configuration
After saving, a confirmation message will appear.
The SWM280 will now be listed with its new IP configuration.
Step 9: Access the WebUI
Open a browser and enter the assigned IP address (e.g., 192.168.1.5). The SWM280 WebUI login screen will appear.
Log in using your SWM280 device credentials. You will find the username and password are located on your device.
Login to device (PROFINET Enabled)
| 5. To enter the managed switch 's Web interface (WebUI), type http://192.168.1.2 into the URL field of your Internet browser. 2. When prompted for authentication enter the username admin and enter the password located on the device information label/engraving. |
|
| 6. After logging in, you must set a new password for security reasons. You will not be able to interact with the managed switch ’s WebUI until the default password is changed. The new password must consist of a minimum of 8 characters. Requirements: one uppercase letter, one lowercase letter, and one digit. |
SWM281 Installation Instructions
Overview
The SWM281 is designed for installation into a standard 19-inch rack cabinet. The mounting brackets are integrated into the device housing and do not require separate attachment.
Important Notice
Before installing the SWM281, review the official spatial measurements and weight information to ensure rack compatibility:
Included Components
- SWM281 device with integrated rack-mount brackets
- Cage nuts
Required Tools
- Phillips screwdriver
- Rack mounting screws
- Cage nut insertion tool (recommended)
Installation Procedure
1. Prepare the Rack
- Select the desired rack unit (U) position for the SWM281.
- Ensure the rack posts are properly aligned and accessible from the front.
- Install cage nuts into the square holes of the rack posts at the selected height:
- Two cage nuts on the left front rack post
- Two cage nuts on the right front rack post
Note: Ensure cage nuts are fully seated in the square holes.

2. Mount the SWM281 into the Rack
- Carefully lift the SWM281 and position it at the selected rack height.
- Align the integrated mounting bracket holes with the cage nuts in the rack posts.
- Insert the rack mounting screws through the bracket holes into the cage nuts.
- Partially tighten all screws to allow for alignment.
- Once aligned, fully tighten all screws on both sides.

3. Verify Installation
- Ensure the device is level and firmly secured.
- Confirm that all mounting screws are fully tightened.
- Gently push the device to verify there is no movement.
Installation Notes
- All expansion bolts for securing the rack base to the ground are installed from bottom to up in the sequence of large flat washer, spring washer, and nut, and the installation holes on the base are flush with the expansion bolts.
- The rack is stable and sturdy after installation has been completed.
- The rack is installed on the ground vertically.
- When multiple racks are placed side by side in the equipment room, they are parallel in a line with a deviation of up to 5 mm (0.20 in.).
- The front and rear doors of the rack can open and close properly after installation has been completed. Also verify that the cabinet locks are functioning and that there are a complete set of keys.
- All labeling on the rack and equipment is accurate.
- Filler panels are installed in the empty slots.
- All the screws and bolts that will be used to install the rack are of the same type.
- All modules installed in the equipment are secured and all captive screws are properly tightened.
- In order to prevent rodents and other small animals from entering the rack, the cabling exit openings at the top and bottom of the rack are fitted with rodent-resistant nets with seams of up to 15 mm (0.59 in.) in diameter.
- The rack always has a set of static-preventive wrist straps available.
Compliance
SWM281 must be used in compliance with any and all applicable national and international laws and with any special restrictions regulating the utilization of the communication module in prescribed applications and environments.
CE Declaration of Conformity
| [BG] Bulgarian | С настоящото TELTONIKA NETWORKS декларира, че този SWM281 е в съответствие със съществените изисквания и други разпоредби на Директиви 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [HR] Croatian | Ovim TELTONIKA NETWORKS izjavljuje da je ovaj SWM281 u skladu s bitnim zahtjevima i ostalim relevantnim odredbama Direktive 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [CZ] Czech | TELTONIKA NETWORKS erklærer hermed, at denne SWM281 er i overensstemmelse med de væsentlige krav og andre bestemmelser i direktiv 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [DK] Danish | Hereby, TELTONIKA NETWORKS declares that this SWM281 is in compliance with the essential requirements and other relevant provisions of Richtlijnen 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [NL] Dutch | Hereby, TELTONIKA NETWORKS declares that this SWM281 is in compliance with the essential requirements and other relevant provisions of Richtlijnen 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [EE] Estonian | Käesolevaga kinnitab TELTONIKA NETWORKS seadme SWM281 vastavust Direktiivide 2014/30/EU, 2014/35/EU, 2011/65/EU põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. |
| [FI] Finish | TELTONIKA NETWORKS vakuuttaa täten että SWM281 tyyppinen laite on Direktiivien 2014/30/EU, 2014/35/EU, 2011/65/EU oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. |
| [FR] French | TELTONIKA NETWORKS déclare par la présente que ce SWM281 est conforme aux exigences essentielles et autres dispositions des Directives 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [DE] German | TELTONIKA NETWORKS erklärt hiermit, dass dieses SWM281 den grundlegenden Anforderungen und anderen Bestimmungen der Richtlinien 2014/30/EU, 2014/35/EU, 2011/65/EU entspricht. |
| [GR] Greek | Η TELTONIKA NETWORKS δηλώνει ότι το παρόν SWM281 συμμορφώνεται με τις βασικές απαιτήσεις και άλλες διατάξεις των Οδηγιών 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [HU] Hungarian | A TELTONIKA NETWORKS kijelenti, hogy ez a SWM281 megfelel a 2014/30/EU, 2014/35/EU, 2011/65/EU irányelvek alapvető követelményeinek és egyéb rendelkezéseinek. |
| [IE] Irish | Leis seo, dearbhaíonn TELTONIKA NETWORKS go gcomhlíonann an SWM281 seo bunriachtanais agus forálacha ábhartha eile Threoir 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [IT] Italian | Con la presente, TELTONIKA NETWORKS dichiara che questo SWM281 è conforme ai requisiti essenziali e ad altre disposizioni pertinenti della Direttive 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [LV] Latvian | TELTONIKA NETWORKS ar šo paziņo, ka šis SWM281 atbilst pamatprasībām un citiem Direktīvas 2014/30/EU, 2014/35/EU, 2011/65/EU noteikumiem. |
| [LT] Lithuanian | Šiuo dokumentu UAB TELTONIKA NETWORKS deklaruoja, kad šis SWM281 atitinka esminius reikalavimus ir kitas 2014/30/EU, 2014/35/EU, 2011/65/EU Direktyvų nuostatas. |
| [MT] Maltese | TELTONIKA NETWORKS b'dan tiddikjara li dan SWM281 jikkonforma mar-rekwiżiti essenzjali u dispożizzjonijiet oħra tad-Direttivi 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [NO] Norwegian | TELTONIKA NETWORKS erklærer herved at denne SWM281 er i samsvar med de grunnleggende kravene og andre bestemmelser i Direktivene 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [PL] Polish | TELTONIKA NETWORKS niniejszym oświadcza, że niniejszy SWM281 jest zgodny z zasadniczymi wymaganiami i innymi postanowieniami Dyrektyw 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [PT] Portuguese | A TELTONIKA NETWORKS declara que esta SWM281 cumpre os requisitos essenciais e outras disposições das Directivas 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [RO] Romanian | TELTONIKA NETWORKS declară prin prezenta că acest SWM281 este în conformitate cu cerințele esențiale și cu alte dispoziții ale Directivelor 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [SK] Slovak | Spoločnosť TELTONIKA NETWORKS týmto vyhlasuje, že tento SWM281 spĺňa základné požiadavky a ďalšie ustanovenia smerníc 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [SI] Slovenian | TELTONIKA NETWORKS izjavlja, da je ta SWM281 skladen z bistvenimi zahtevami in drugimi določbami Direktiv 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [ES] Spanish | TELTONIKA NETWORKS declara por la presente que este SWM281 cumple los requisitos esenciales y otras disposiciones de las Directivas 2014/30/EU, 2014/35/EU, 2011/65/EU. |
| [SE] Swedish | TELTONIKA NETWORKS förklarar härmed att denna SWM281 uppfyller de grundläggande kraven och andra bestämmelser i Direktiven 2014/30/EU, 2014/35/EU, 2011/65/EU. |
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
ISED Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference;
- This device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
- L'appareil ne doit pas produire de brouillage;
- L'appareil doit accepter tout brouillage radioélectrique subi, mźme si le brouillage est.
Detailed compliance information is available at the following internet address: wiki.teltonika-networks.com/view/Certificates.
This sign means that is necessary to read the User's Manual before you start using the device.
This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste.
Hereby, TELTONIKA NETWORKS declares that this SWM281 is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: https://wiki.teltonika-networks.com/view/SWM281_CE/RED
Hereby, TELTONIKA NETWORKS declares that the radio equipment type SWM281 is in compliance with Radio Equipment Regulations 2017. The full text of the UK declaration of conformity is available at the following internet address: https://wiki.teltonika-networks.com/view/SWM281_UKCA.
Operating conditions
- Operating temperature: 0° to +50° Celsius
- Humidity should be in the range of 5% to 95% (non-condensing). Only use the device in dry environments.
- Out of direct sunlight
- Away from heat source, corrosive substances, salts, and flammable gases
Attention: operation outside the permissible range can considerably shorten the service life of the device.
Faulty and damaged products
- Do not attempt to disassemble the device or its accessories.
- Only qualified personnel must service or repair the device or its accessories.
- If your device or its accessories have been submerged in water punctured or subjected to a severe fall, do not use until they have been checked at an authorized service center.
Electrical safety
- Only use approved accessories.
- Do not connect with incompatible products or accessories.
- It is recommended to ground devices with grounding terminals before connecting them to power. Failure to ground appropriately might result in a shock hazard. The cross-sectional area of the protective grounding conductor should be at least 1mm2.
- Always observe the local regulations and standards. Only trained and qualified personnel should be allowed
to operate the equipment.
- Carefully check your work area for possible hazards, such as ungrounded power extension cables, missing safety grounds, and moist floors.
- Locate the emergency power-off switch in the room. In the case of an electrical accident, you will be able to quickly turn off the power.
- Never assume that power is disconnected from a circuit. Instead, always check.
- Do not subject the equipment to dampness and avoid liquid inside the equipment.
Danger
- Improper electric operations may cause a fire, electric shock, and other accidents, which may lead to severe and fatal personal injury and equipment damage.
- Direct or indirect touch through a wet object with high-voltage and mains supply can bring a fatal danger.
Laser safety
The optical transceivers are Class I laser products. Attention should be paid to the following items:
- When an optical transceiver is working, ensure that the port is connected to an optical cable or covered by dust cap to keep out dust and prevent burning your eyes.
- Do not stare into any optical port.
Danger
- Do not approach or stare into any optical port under any circumstances. This may cause permanent damage to your eyes.
System Grounding
A reliable grounding system is the basis for stable and reliable operation, which is indispensable for preventing lightning strikes and interference. Carefully check the grounding conditions at the installation site according to the grounding specifications, and complete grounding properly based on the site situation.
- Safety Grounding
Ensure that the rack and power distribution system are securely grounded. Otherwise, electric shocks may occur when the insulation resistance between the power module and the chassis becomes small.
Caution
The building should provide a protective ground connection to ensure that the equipment is connected to a protective earth.
Product handling
- You alone are responsible for how you use your device and any consequences related to its use.
- Use of your device is subject to safety measures designed to protect users and their environment.
- Always treat your device and its accessories with care and keep it in a clean and dust-free place.
- Do not expose your device or its accessories to open flames, lit tobacco products, liquid, moisture, or high humidity.
- Do not drop, throw or try to bend your device or its accessories.
- Do not use harsh chemicals, cleaning solvents, or aerosols to clean the device or its accessories.
- Do not paint your device or its accessories.
- Do not attempt to disassemble your device (exemptions for devices that require disassembly for SIM insertion) or its accessories: it does not contain any user-serviceable parts. For safety reasons, the equipment should be opened only by qualified personnel.
- Make sure to use ESD personal protective equipment while the equipment is serviced.
- Do not use your device in an enclosed environment where heat dissipation is poor.
- Prolonged use in such space may cause excessive heat and raise ambient temperature, which will lead to the automatic shutdown of your device or the disconnection of the mobile network connection for your safety. To use your device again after such a shutdown, cool it in a well-ventilated place before turning it on.
- Please check all national laws and local regulations for the disposal of electronic products.
- Do not operate the device where ventilation is restricted.
- Do not use or install this product near water to avoid fire or shock hazards.
- Avoid exposing the equipment to rain or damp areas.
- Arrange power and Ethernet cables so that they are not likely to be stepped on or have items placed on them.
- Ensure that the voltage and the rated current of the power source match the device’s requirements. Do not connect the device to an inappropriate power source.
- During a thunderstorm, no operations should be carried out on the device and cables.
- The unit must be powered off where blasting is in progress and explosive atmospheres are present or near medical life support equipment.
- Do not leave your device and its accessories within reach of small children or allow them to play with it. They could hurt themselves or others and could accidentally damage the device. Your device contains small parts with sharp edges that may cause an injury choking hazard.
- The device may become warm during regular use.
- Operation of this equipment in a residential environment could cause radio interference.
- This equipment is not suitable for use in locations where children are likely to be present.
- This equipment should be installed in the equipment room. Only a skilled person should be allowed to install, replace, or service this equipment. Do not open the enclosure when the equipment is running. Cut off the power supply before opening the enclosure in case of an electric shock.