Field | Value | Description |
---|---|---|
Enable | off | on; default: off | Turns TR-069 client on or off. |
Periodic enable | off | on; default: on | Turns periodic data transmissions to server on or off. |
Accept server request | off | on; default: off | When enabled the device accepts connection requests from servers. |
Sending interval | integer [60..9999999]; default: 100 | Periodic data transmission frequency (in seconds). |
Username | string; default: easycwmp | Username used for authentication to a TR-069 server. |
Password | string; default: easycwmp | Password used for authentication to a TR-069 server. |
URL | host | ip; default: http://192.168.1.110:8080/openacs/acs | IP address or hostname of a TR-069 server. |
Management via TR-069
TR-069 can be used to set or get values from RUT devices. Below is a list of commands used for device management via TR-069.
- R - read only;
- RW - read/write;
- string(64) - 64 bit string;
- string(256) - 256 bit string;
- unsignedInt - integer storing only positive values.
Device Information:
- DeviceInfo.HardwareVersion - device hardware version (e.g., 0201) R
- DeviceInfo.Manufacturer - device manufacturer (e.g., Teltonika) R
- DeviceInfo.ManufacturerOUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
- DeviceInfo.ProductClass - device model (e.g., RUT140) R
- DeviceInfo.ProvisioningCode - provisioning code R
- DeviceInfo.SerialNumber - device serial number (e.g., 1000111111) R
- DeviceInfo.SoftwareVersion - device software version (e.g., RUT14X_R_00.0X.XX) R
- DeviceInfo.SpecVersion - device special version (e.g., 1.0) R
Device IP interface information:
- IP.Interface.1.Enable - interface enabled/disabled (e.g., true) R
- IP.Interface.1.IPv4Address.1.Enable - IPv4 address enabled/disabled (e.g., 1) R
- IP.Interface.1.IPv4Address.1.IPAddress - IPv4 address (e.g., 192.168.1.1) R
- IP.Interface.1.Name - interface name (e.g., lan) R
Device Management Server information:
- ManagementServer.ConnectionRequestPassword - connection request password (e.g., randompassword) RW
- ManagementServer.ConnectionRequestURL - connection request URL R
- ManagementServer.ConnectionRequestUsername - connection request username (e.g., 001E42-RUTX14-0000000000) RW
- ManagementServer.ParameterKey - server parameter key R
- ManagementServer.Password - server password RW
- ManagementServer.PeriodicInformEnable - enabled/disabled TR-069 client periodic data transmission to TR-069 server (e.g., true) RW
- ManagementServer.PeriodicInformInterval - periodic data transmission interval (e.g., 300) RW
- ManagementServer.PeriodicInformTime - periodic information time (e.g., 1/1/1970, 8:09:27 PM) RW
- ManagementServer.URL - server URL RW
- ManagementServer.Username - server username RW
Device ID information:
- DeviceID.ID - device ID (e.g., 001E42-RUTX14-0000000000) R
- DeviceID.Manufacturer - device manufacturer (e.g., Teltonika) R
- DeviceID.OUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
- DeviceID.ProductClass - product class (e.g., RUTXXX) R
- DeviceID.SerialNumber - device serial number R
Events information:
- Events.0_BOOTSTRAP - bootstrap time R
- Events.1_BOOT - boot time R
- Events.Inform - information time R
- Events.Registered - events reg time R