TR-069 (Technical Report 069) is an application layer protocol designed for management of equipment connected to a remote network.

This chapter of the user manual provides an overview of the UPnP page in RUT271 devices.


TR-069 is additional software that can be installed from the System → Package Manager page.

TR-069 Client Configuration

Field Value Description
Enable off | on; default: off Turns TR-069 client on or off.
Periodic enable off | on; default: on Turns periodic data transmissions to server on or off.
Accept server request off | on; default: off When enabled the device accepts connection requests from servers.
Sending interval integer [60..9999999]; default: 100 Periodic data transmission frequency (in seconds).
Username string; default: easycwmp Username used for authentication to a TR-069 server.
Password string; default: easycwmp Password used for authentication to a TR-069 server.
URL host | ip; default: http://192.168.1.110:8080/openacs/acs IP address or hostname of a TR-069 server.

Management via TR-069

TR-069 can be used to set or get values from RUT devices. Below is a list of commands used for device management via TR-069.

  • R - read only;
  • RW - read/write;
  • string(64) - 64 bit string;
  • string(256) - 256 bit string;
  • unsignedInt - integer storing only positive values.

Device Information:

  1. DeviceInfo.HardwareVersion - device hardware version (e.g., 0201) R
  2. DeviceInfo.Manufacturer - device manufacturer (e.g., Teltonika) R
  3. DeviceInfo.ManufacturerOUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
  4. DeviceInfo.ProductClass - device model (e.g., RUT271) R
  5. DeviceInfo.ProvisioningCode - provisioning code
  6. DeviceInfo.SerialNumber - device serial number (e.g., 1000111111) R
  7. DeviceInfo.SoftwareVersion - device software version (e.g., RUT2M_R_00.0X.XX) R
  8. DeviceInfo.SpecVersion - device special version (e.g., 1.0) R

Device Mobile Information:

  1. MobileInfo.Modem.1-1.CellID - cell ID
  2. MobileInfo.Modem.1-1.ConnState - connection state (e.g., Connected) R
  3. MobileInfo.Modem.1-1.ConnType - connection type (e.g., LTE) R
  4. MobileInfo.Modem.1-1.EARFCN - absolute radio frequency channel number (e.g., 75) R
  5. MobileInfo.Modem.1-1.ECIO - signal, measured in dB R
  6. MobileInfo.Modem.1-1.ICCID - SIM ICCID R
  7. MobileInfo.Modem.1-1.IMEI - modem IMEI R
  8. MobileInfo.Modem.1-1.IMSI - international mobile subscriber identity R
  9. MobileInfo.Modem.1-1.LAC - location area code R
  10. MobileInfo.Modem.1-1.Manufacture - modem manufacture R
  11. MobileInfo.Modem.1-1.Model - modem model R
  12. MobileInfo.Modem.1-1.NeighbourCells - neighbour cells (e.g., intra,LTE,75,109,-13,-104,-71,0,23,5,12,10,255) R
  13. MobileInfo.Modem.1-1.NetState - operator state (e.g., Registered, home) R
  14. MobileInfo.Modem.1-1.Operator - operator name R
  15. MobileInfo.Modem.1-1.OperatorNum - operator number R
  16. MobileInfo.Modem.1-1.PCI - physical cell identity R
  17. MobileInfo.Modem.1-1.PinState - pin state (e.g., OK) R
  18. MobileInfo.Modem.1-1.RSCP - signal, measured in dBm R
  19. MobileInfo.Modem.1-1.RSRP - signal, measured in dBm R
  20. MobileInfo.Modem.1-1.RSRQ - signal, measured in dB R
  21. MobileInfo.Modem.1-1.RSSI - signal, measured in dBm R
  22. MobileInfo.Modem.1-1.ReceivedThisMonth - data received this month R
  23. MobileInfo.Modem.1-1.ReceivedToday - data received today R
  24. MobileInfo.Modem.1-1.Revision - modem firmware R
  25. MobileInfo.Modem.1-1.SINR - signal, measured in dB R
  26. MobileInfo.Modem.1-1.SentThisMonth - data sent this month R
  27. MobileInfo.Modem.1-1.SentToday - data sent today R
  28. MobileInfo.Modem.1-1.Serial - modem serial number R
  29. MobileInfo.Modem.1-1.SimState - sim state (e.g., Inserted) R
  30. MobileInfo.Modem.1-1.TAC - tracking area code R
  31. MobileInfo.Modem.1-1.Temperature - modem temperature R

Device IP interface information:

  1. IP.Interface.1.Enable - interface enabled/disabled (e.g., true) R
  2. IP.Interface.1.IPv4Address.1.Enable - IPv4 address enabled/disabled (e.g., 1) R
  3. IP.Interface.1.IPv4Address.1.IPAddress - IPv4 address (e.g., 192.168.1.1) R
  4. IP.Interface.1.Name - interface name (e.g., lan) R

Device Management Server information:

  1. ManagementServer.ConnectionRequestPassword - connection request password (e.g., randompassword) R
  2. ManagementServer.ConnectionRequestURL - connection request URL R
  3. ManagementServer.ConnectionRequestUsername - connection request username (e.g., 001E42-RUTX14-0000000000) R
  4. ManagementServer.ParameterKey -
  5. ManagementServer.Password -
  6. ManagementServer.PeriodicInformEnable - enabled/disabled TR-069 client periodic data transmission to TR-069 server (e.g., true) R
  7. ManagementServer.PeriodicInformInterval - periodic data transmission interval (e.g., 300) R
  8. ManagementServer.PeriodicInformTime - periodic information time (e.g., 1/1/1970, 8:09:27 PM) R
  9. ManagementServer.URL - server URL R
  10. ManagementServer.Username - server username R

Device ID information:

  1. DeviceID.ID - device ID (e.g., 001E42-RUTX14-0000000000) R
  2. DeviceID.Manufacturer - device manufacturer (e.g., Teltonika) R
  3. DeviceID.OUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
  4. DeviceID.ProductClass - product class (e.g., RUTXXX) R
  5. DeviceID.SerialNumber - device serial number R

Events information:

  1. Events.0_BOOTSTRAP - bootstrap time R
  2. Events.1_BOOT - boot time R
  3. Events.Inform - information time R
  4. Events.Registered - events reg time R