Averaged RUT300 power consumption values in different states of operation are represented in the tables below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
68
0.61
Idle (12 V)
53
0.64
Idle (24 V)
29
0.70


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 (9 V)
114
1.03
2 LAN devices connected 1 (12 V)
86
1.03
2 LAN devices connected 1 (24 V)
45
1.08


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V)
497
4.47
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V)
373
4.48
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V)
192
4.61

1 - Data streams between RUT300 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
3 - USB device with ~ 500 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.