Jump to content

RUT301 Power Consumption

From Teltonika Networks Wiki
Main Page > RUT Routers > RUT301 > RUT301 Manual > RUT301 Power Consumption

Averaged RUT301 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
60.43
0.54
Idle (12 V)
48.19
0.58
Idle (24 V)
32.42
0.78
Idle (30 V)
30.85
0.93


Test type
Current (mA)
Power consumption (W)
1 LAN device connected 1 (9 V)
99.46
0.89
1 LAN device connected 1 (12 V)
75.96
0.91
1 LAN device connected 1 (24 V)
47.53
1.14
1 LAN device connected 1 (30 V)
43.82
1.31


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V)
615.85
5.54
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V)
499.72
6
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V)
255.74
6.14
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (30 V)
209.76
6.29


1 - Data streams between RUT300 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
3 - USB device with ~ 500 mA current draw.