Product change notifications (PCN) is way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc.
This page stores information regarding changes made to the RUTM56 device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2026.07.20: SDK Changes
With the release of RutOS version 7.25 in 2026 Q4, changes will be introduced to the Software Development Kit (SDK) used for firmware compilation on RUTM56 devices.
PCN Number: PCN_RUTM56_SDK Changes_2026.07.20
Change description
Change type
Software change (SDK structure and build system)
Detailed description
Starting with RutOS version 7.25, the Software Development Kit (SDK) used for compiling device firmware will be updated and migrated to a new build system and SDK structure.
This change affects customers who use the SDK to develop and compile custom firmware images. Existing custom SDK-based solutions may no longer be directly compatible with the updated SDK structure and tooling.
Customers intending to compile firmware based on RutOS version 7.25 or newer will need to adapt their custom SDK solutions to align with the new SDK structure and compilation system.
Devices running standard Teltonika firmware images without custom SDK usage are not affected by this change.
Change reasons
To migrate the firmware compilation process to a build system and SDK structure that is better aligned with internal development requirements and long-term maintenance goals.
Affected products information
Model
Affected order codes
Order code changes
RUTM56
RUTM56 *****
No changes
Upcoming change date
2026 Q4, with the release of RutOS 7.25
Change impact
Risk assessment
SDK compatibility risk: Customers using custom SDK-based firmware solutions will need to modify and adapt their existing SDK integrations to be compatible with the new SDK structure introduced in RutOS 7.25.
Compilation impact: Existing custom build scripts, tools, or workflows may no longer function without changes when compiling firmware based on RutOS 7.25 or newer.
No impact on standard users: Customers using official Teltonika firmware images without SDK customization are not affected by this change.
Operational continuity: Devices already deployed in the field remain fully operational and are not impacted unless a firmware recompilation using the updated SDK is required.
Suggested implementation plan
Customers using the SDK for custom firmware development should review and adapt their existing SDK solutions to the updated SDK structure before migrating to RutOS version 7.25 or newer.
It is recommended to validate custom firmware builds in a test environment prior to deployment.
For additional guidance regarding SDK changes and adaptation, please contact your sales representative or Teltonika support.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the PDF version of this notification, click here.
2026.06.19: Packaging Box Changes
Beginning in 2026 September, the mass packaging for RUTM56 will updated with the following changes.
Starting in 2026 September, packaging of the RUTM56 device will be updated. Crumpled paper filler will replace the previously used plastic filler in shipping cartons to fill empty spaces and provide additional protection during transportation.
Please note that this change will be implemented gradually, throughout a 2-month transitional period starting from September, 2026. During this period, your shipments of RUTM56 may consist of either the current design or the new one described above.
Current packaging:
Updated packaging:
Change reasons
Enhanced Product Protection: Individual packaging ensures better protection during handling and transit.
Sustainability & Waste Reduction: Optimized packaging reduces material waste and improves overall environmental sustainability.
Affected products information
Model
Affected order codes
Order code changes
RUTM56
RUTM56 ******
N/A
Upcoming change date
2026 September
Change impact
Risk assessment
Changes to packaging materials may impact packaging-related documentation and visual assets that reference the previous packaging configuration.
No impact on product functionality or technical specifications.
Suggested implementation plan
Inform relevant warehouse and logistics personnel about the packaging changes.
If necessary, contact your sales representative for further guidance and support.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2025.08.25: Updated enclosure design
Starting from Q3 2025, the enclosure of RUTM56 devices will be replaced with a new single-piece anodized design.
The updated enclosure is now made from a single piece instead of two separate parts.
Casing dimensions remain unchanged, but the depth and location of the grooves are different. See the images below for exact placement.
Engraving will be used instead of stickers for markings.
The new enclosure will be anodized instead of painted. Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q3 2025. During this period, your shipments of RUTM56 may consist of either the current or the new enclosure as described above.
Additional details
Illustrations
Finish details
New enclosure
Old enclosure
Change reasons
To improve structural integrity, reduce waste, and simplify assembly.
Affected products information
Model
Affected order codes
Order code changes
RUTM56
All
No changes
Upcoming change date
Q3 2025
Change impact
Risk assessment
Marketing materials, such as photos, may need to be replaced.
Engraved markings are permanent and cannot be removed like stickers.
The anodized finish may alter the surface colour and reflectivity.
Changes to groove depth and placement may affect accessory compatibility.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may assume tacit acceptance and proceed with the enclosure update as described.
To download the PDF version of this notification, click here.
2025.08.21: eSIM Bootstrap capability
Starting from 2026 Q1, RUTM56 eSIM will include a bootstrap profile, which enables the download of an initial operational eSIM profile without requiring an additional internet connection.
Change Notification!
As of 2025-11-24 an additional revision has been made to this PCN document: previous change date of 2025 Q4 was revised an is now 2026 Q1
As of 2025-09-03, a revision has been made to this PCN document: clarification added that Bootstrap functionality is officially supported from firmware version RUTM_R_00.07.17.2 or newer.
PCN Number: PCN_RUTM56_esim_bootstrap_2025.08.21
Change description
Change type
eSIM service enhancement
Detailed description
• Addition of bootstrap profile to eSIM
• Automated SIM switching functionality when no physical SIM is present and bootstrap profile is active
• Device with active bootstrap profile will have access only to RMS (Remote Management System) with limited functionality and SM-DP server for downloading operational profile
• Bootstrap profile has a 10 MB mobile data limit
• Bootstrap profile is valid for 1 year, starting from the manufacturing date of the device
Read the following eSIM Bootstrap guide to familiarize yourself with the functionality.
Bootstrap functionality is officially supported from firmware version RUTM_R_00.07.17.2 or newer.
Change reasons
Simplified eSIM activation process and improved provisioning automation
Affected products information
Model
Affected order codes
Order code changes
RUTM56
RUTM56 0*****
No changes
Upcoming change date
2026 Q1
Change impact
Risk assessment
• Device initial provisioning workflows may require review or adjustment to account for the presence of a bootstrap profile
• Installation procedures or automated deployment tools may need to be updated if they rely on predefined SIM behavior
• Automatic SIM switching will be enabled only on devices shipped with a pre-installed bootstrap profile — existing devices with eSIM but no bootstrap profile will not exhibit any behavioral changes
• Devices manufactured over 12 months prior to activation may be unable to use the bootstrap profile due to expiration
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. Learn more eSIM Bootstrap. For more detailed information, please contact your sales representative.
Supported country list
EMEA
APAC
AMERICAS
Territories / Special Regions
Albania
Austria
Belgium
Bulgaria
China
Brazil
Gibraltar
Croatia
Cyprus
Czech Republic
Denmark
Hong Kong
Canada
Guadeloupe
Estonia
Finland
France
Georgia
Colombia
Northern Mariana Islands
Germany
Greece
Hungary
Iceland
Indonesia
Costa Rica
Réunion
Ireland
Italy
Latvia
Liechtenstein
Malaysia
Mexico
Lithuania
Luxembourg
Malta
Montenegro
Singapore
United States of America
Netherlands
Norway
Poland
Portugal
Sri Lanka
Romania
Slovakia
Slovenia
South Africa
Taiwan
Spain
Sweden
Switzerland
United Kingdom
Vietnam
Egypt
Saudi Arabia
Kuwait
Qatar
Australia
Turkey
Tunisia
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the PDF version of this notification, click here.
2025.04.22: Transition to HTTPS protocol RutOS 7.15
With the release of RutOS version 7.15 in Q2 2025, RUTM56 devices will disable the HTTP protocol and enable HTTPS Redirect by default to enhance WebUI and API communication security.
With the release of RutOS version 7.15 firmware, the device's WebUI and API default communication methods will change. The HTTP protocol will be changed to HTTPS (only) in default configuration for security reasons and complying with security standards. The "HTTPS Redirect" functionality will be enabled by default so all HTTP requests will be automatically redirected through the HTTPS channel.
Change reasons
To enhance security measures and comply with security standards by eliminating unsecured HTTP protocol usage.
Affected products information
Model
Affected order codes
Order code changes
RUTM56
All
No changes
Upcoming change date
Q2 2025
Change impact
Risk assessment
Users may receive a browser warning indicating that the connection is not secure due to the use of a self-signed certificate in HTTPS.
API users may experience issues depending on the tools they use to communicate with the API, as some may not support HTTPS, self-signed certificates or the tooling may have to be reconfigured to adapt to these changes.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. URL1URL2 For more detailed information, please contact your sales representative.
API users should update their tools and scripts to support HTTPS communication and handle self-signed certificates.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the PDF version of this notification, click here.