RUTX50 Product Change Notifications

From Teltonika Networks Wiki
Main Page > RUTX Routers > RUTX50 > RUTX50 Product Change Notifications

Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).

This page stores information regarding changes to the RUTX50 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).

2024.03.08: Reset button functionality change RutOS 7.07

With the release of RutOS version 7.07, RUTX50 device will experience changes related to the security improvements of the device.

PCN Number: PCN_RUTOS_CHANGE_2024_03_08_EN
Change description
Change type Firmware change
Detailed description Previously, during device resets, logs, RMS connection state data, and SIM PIN settings remained unchanged. However, starting with RutOS firmware version 7.07, all devices will uniformly reset logs, RMS connection state data, and SIM PIN settings to factory defaults when using the reset button. Other reset methods, including WebUI, SMS, and others, will remain unimpacted by this change.
Change reasons Increasing security
Affected products information
Model Affected order codes Order code changes
RUTX50 RUTX50 ****** No changes
Upcoming change date 2024 Q2, with the release of RutOS 7.07
Change impact
Risk assessment
  • The loss of device logs upon utilizing the reset button may disrupt operational records and slow down subsequent troubleshooting efforts.
  • Failure to set up the SIM PIN post-reset via the reset button may result in SIM card lockout due to repeated incorrect PIN entries, causing service disruption and requiring either SIM replacement or PIN reset.
  • The device is still visible in RMS post-reset but cannot be accessed. Therefore, re-adding the device to RMS is necessary for continued access.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

{{{Full_date}}}: Visual colour housing changes

Beginning in April 2024, RUTX50 router will be manufactured with a different colour housing.

PCN Number: PCN_RUTX50_{{{Full_date}}}_EN
Change description
Change type Housing colour
Detailed description RUTX50 devices will be produced with a new black housing.


Please note that this change will be implemented gradually, throughout a 3-month transitional period starting in April 2024. During this period, your shipments of RUTX50 may consist of either the current design or the new one described above.

Current design:

RUTX50 silver housing 1.png
New design:

RUTX50 black housing 1.png
The housing dimensions will not be changed.
Change reasons Design improvement.
Affected products information
Model Affected order codes Order code changes
RUTX50 RUTX50 ****** N/A
Upcoming change date 2024 April
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Marketing material regarding the changes will be found at our wiki: https://wiki.teltonika-networks.com/view/RUTX50_Marketing_Material
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, [[Media:PCN_RUTX50_{{{File_Full_date}}}_EN_Packaging.pdf|click here]].

2023.10.30: Firmware Requirement Change

Starting November 2023 with batch 16, all RUTX50 devices will be manufactured with a new firmware version and will support only firmware version RUTX_R_00.07.05.3 or newer.

Change description
Change type Firmware Requirement Change
Detailed description Starting November 2023 with batch 16, all RUTX50 devices will be manufactured with a new firmware version. They will require firmware version RUTX_R_00.07.05.3 or newer. Downgrading to previous firmware versions will no longer be supported.

Please note that your RUTX50 shipments may include either the prior version or the newly described version above due to stocked devices.

Change reason Support for the new SPI Nand Flash memory
Affected products information
All RUTX50 ****** product codes are affected. No product code changes.
Upcoming change date November 2023, batch 16
Change impact
Risk assessment All risks are firmware-related. Firmware downloads for the device can be found here.

Please note: this product change notification does not affect any previous RUTX50 devices, except newly manufactured RUTX50 devices.

Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2023.08.02: Product packaging changes

Starting from 2023 Q3 RUTX50 product packaging will be changed.

Change description
Change type Packaging
Detailed description The packaging for the product will undergo several updates including an update to the side print of the box. Additionally, the box will now feature press with certificates that will be printed according to the region. Finally, there will also be changes made to the company information section including the address, telephone number, email and website link.
Current design:

Old product box marking 2023.png
Updated packaging design:

New product box markings 2023.png
Packaging dimensions will not change.
Change reasons Design improvement.
Affected products information
Model Affected order codes Order code changes
RUTX50 RUTX50 ***** No changes
Upcoming change date 2023 Q3
Change impact
Risk assessment The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2023.02.13: MAC address range change

All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.

Change description
Change type MAC address range
Detailed description All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons Endpoint of the previous MAC address range.
Affected products information
Model Affected order codes Order code changes
All Teltonika Networks devices All order codes No changes
Upcoming change date 2023, week 9
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.