Averaged SWM280 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (A)
Power consumption (W)
Idle (230 V AC)
0.0367
8.43


Test type
Current (A)
Power consumption (W)
24 eth ports idle (230 V AC)
0.0937
21.56


Test type
Current (A)
Power consumption (W)
24 eth ports ethernet full load1 (230 V AC)
0.0953
21.91


Test type
Current (A)
Power consumption (W)
24 eth + 4sfp ethernet full load1 (230 V AC)
0.105
24.23


Test type
Current (A)
Power consumption (W)
24 eth + 4sfp + POE 300W(12port) (230 V AC)
1.424
327.57


Test type
Current (A)
Power consumption (W)
24 eth + 4sfp + POE 150W(12port) (230 V AC)
0.775
178.24

1 - Data streams between devices were created using iPerf3.