→‎Trap Rules: Update current device SNMP information.
Line 296: Line 296:  
You can create a new trap rule by clicking the 'Add' button.
 
You can create a new trap rule by clicking the 'Add' button.
   −
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_add_button.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_add_button_v1.png|border|class=tlt-border]]
    
You should be redirected to the rule's configuration page which should look something like this:
 
You should be redirected to the rule's configuration page which should look something like this:
   −
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_modify_trap_rule_mobile_{{{mobile}}}.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_modify_trap_rule_mobile_1.png|border|class=tlt-border]]
    
Above is an example of what rule configuration window looks like. Below is a table with detailed explanations on how to configure the rule and what each of the fields mean.  
 
Above is an example of what rule configuration window looks like. Below is a table with detailed explanations on how to configure the rule and what each of the fields mean.  
    
To avoid redundancy, screenshots for the other rules will not be provided, since the structures, syntax and the overall look of the configuration windows for each rule are very similar. Instead, only tables containing information on how to edit each rule will be provided.
 
To avoid redundancy, screenshots for the other rules will not be provided, since the structures, syntax and the overall look of the configuration windows for each rule are very similar. Instead, only tables containing information on how to edit each rule will be provided.
 +
 
{{#ifeq: {{{mobile}}} | 1 |
 
{{#ifeq: {{{mobile}}} | 1 |
====Signal strength====
+
====GSM====
 
----
 
----
 
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 315: Line 316:  
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Enable</td>
+
         <td>Trap type</td>
         <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
+
         <td>GSM <nowiki>|</nowiki> Input/Output; default: <b>GSM</b></td>
         <td>Enable or disable this rule.</td>
+
         <td>The type of SNMP Trap rule. In this case GSM.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Action</td>
+
         <td>Trigger</td>
         <td>Signal strength trap</td>
+
         <td>Signal strength <nowiki>|</nowiki> Network type; default: <b>Signal strength</b></td>
         <td>Rule will be triggered if signal strength falls below specified number.</td>
+
         <td>The trigger which invokes the rule. Possible triggers:
 +
            <ul>
 +
                <li><b>Signal strength</b> - Rule will be triggered if signal strength falls below specified number.</li>
 +
                <li><b>Network type</b> - Rule will be triggered if network connection type changes.</li>
 +
            </ul></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 331: Line 336:  
</table>
 
</table>
 
<br>
 
<br>
====Connection type====
+
|}}
 +
====Input/Output====
 
----
 
----
 
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 341: Line 347:  
     <tr>
 
     <tr>
 
         <td>Enable</td>
 
         <td>Enable</td>
         <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
+
         <td>off | on; default: <b>off</b></td>
 
         <td>Enable or disable this rule.</td>
 
         <td>Enable or disable this rule.</td>
 
     </tr>
 
     </tr>
   
     <tr>
 
     <tr>
         <td>Action</td>
+
         <td>Trap type</td>
         <td>Connection type trap</td>
+
        <td>{{#ifeq: {{{mobile}}} | 1 |GSM <nowiki>|</nowiki> |}}Input/Output; default: {{#ifeq: {{{mobile}}} | 1 |GSM|Input/Output}}</td>
         <td>Rule will be triggered when connection type will change.</td>
+
        <td>The type of SNMP Trap rule. In this case Input/Output.</td>
 +
    </tr>
 +
{{#switch:{{{series}}}
 +
|RUTX|RUTM =
 +
    <tr>
 +
        <td>Trigger</td>
 +
         <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
 +
        <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
    </tr>
 +
    <tr>
 +
         <td>State change</td>
 +
        <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
|TRB2 =
 +
    <tr>
 +
        <td>Trigger</td>
 +
        <td><span style="color:red">Analog input(11)</span> {{!}} Configurable Input/Output (2) {{!}} Configurable Input/Output (3) {{!}} Configurable Input/Output (4); default: Analog Input(11)</td>
 +
        <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>State change</td>
 +
        <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 
     </tr>
 
     </tr>
</table>
  −
<br>|}}
  −
====Input/Output====
  −
----
  −
<table class="nd-mantable">
   
     <tr>
 
     <tr>
         <th>field name</th>
+
         <td><span style="color:red">Analog input(11):</span> State change</td>
         <th>value1</th>
+
         <td>In range {{!}} Out of range {{!}} Both; default: <b>Both</b></td>
         <th>description</th>
+
         <td>On which Input/Output state will this rule be triggered.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Enable</td>
+
         <td><span style="color:red">Analog input(11):</span> Min voltage</td>
         <td>off | on; default: <b>off</b></td>
+
         <td>positive float; default: <b>none</b></td>
         <td>Enable or disable this rule.</td>
+
         <td>At which minimum voltage value will this rule be triggered.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Action</td>
+
         <td><span style="color:red">Analog input(11):</span> Max voltage</td>
         <td>Input/Output trap</td>
+
         <td>positive float; default: <b>none</b></td>
         <td>Rule will be triggered when specified input or output state will change.</td>
+
         <td>At which maximum voltage value will this rule be triggered. Must be higher than Min voltage.</td>
 
     </tr>
 
     </tr>
{{#switch:{{{series}}}
+
|TRB1 =
|RUTX|RUTM =
+
    {{#ifeq:{{{name}}}|TRB141|
 
     <tr>
 
     <tr>
         <td>Input/Output type</td>
+
         <td>Trigger</td>
         <td>Input/Output; default: <b>Input/Output</b></td>
+
         <td><span style="color:red">Analog Current Loop (7)</span> {{!}} <span style="color:red">Analog Input (7)</span> {{!}} <span style="color:blue">Passive/Active input (Dry/Wet) (1)</span> {{!}} <span style="color:blue">Passive/Active input (Dry/Wet) (2)</span> {{!}} Configurable Input/Output (3) {{!}} Configurable Input/Output (4) {{!}} Isolated Input (8,16) {{!}} <span style="color:green">Relay (3,4,5)</span> {{!}} <span style="color:green">Latching Relay (11,12,13)</span>; default: Analog Current Loop (7)</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Input/Output name</td>
+
         <td>State change</td>
         <td>Output(4) {{!}} Input(3); default: <b>Output(4)</b></td>
+
        <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:red">Analog Current Loop (7), Analog Input (7):</span> State change</td>
 +
        <td>In range {{!}} Out of range {{!}} Both; default: <b>Both</b></td>
 +
         <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:blue">Passive/Active input (Dry/Wet):</span> State change</td>
 +
        <td>Rising {{!}} Falling {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:green">Relay (3,4,5), Latching Relay (11,12,13):</span> State change</td>
 +
        <td>Open {{!}} Closed {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:red">Analog Current Loop (7), Analog Input (7):</span> Min voltage</td>
 +
        <td>positive float; default: <b>none</b></td>
 +
        <td>At which minimum voltage value will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:red">Analog Current Loop (7), Analog Input (7):</span> Max voltage</td>
 +
        <td>positive float; default: <b>none</b></td>
 +
        <td>At which maximum voltage value will this rule be triggered. Must be higher than Min voltage.</td>
 +
    </tr>
 +
    |
 +
    <tr>
 +
        <td>Trigger</td>
 +
        <td>Configurable Input/Output (3) {{!}} Configurable Input/Output (4); default: <b>Configurable Input/Output (3)</b></td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>State change</td>
 
         <td>State change</td>
         <td>High level {{!}} Low level {{!}} Both; default: <b>High level</b></td>
+
         <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 
         <td>On which Input/Output state will this rule be triggered.</td>
 
         <td>On which Input/Output state will this rule be triggered.</td>
     </tr>
+
     </tr>}}
|TRB2 =
+
|RUT36X =
 
     <tr>
 
     <tr>
         <td>Input/Output type</td>
+
         <td>Trigger</td>
         <td><span style="color:blue">Input/Output</span> {{!}} <span style="color:red">ADC</span>; default: <b>Input/Output</b></td>
+
         <td>Configurable Input/Output (3) {{!}} Configurable Input/Output (4); default: <b>Configurable Input/Output (3)</b></td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td><span style="color:blue">Input/Output:</span> Input/Output name</td>
+
         <td>State change</td>
         <td>Configurable Input/Output([2..4]); default: <b>Configurable Input/Output(2)</b></td>
+
        <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
|RUT9 =
 +
    {{#ifeq:{{{name}}}|RUT955|
 +
    <tr>
 +
        <td>Trigger</td>
 +
         <td><span style="color:red">Analog Current Loop (6,9)</span> {{!}} <span style="color:red">Analog Input (6,9)</span> {{!}} Input (3) {{!}} Digital Input (1) {{!}} Output (4) {{!}} Isolated output (3,4,8) {{!}} Isolated Input (2,7) {{!}} <span style="color:blue">Relay (5,10)</span>; default: Analog Current Loop (6,9)</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td><span style="color:blue">Input/Output:</span> State change</td>
+
         <td>State change</td>
 
         <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 
         <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
 
         <td>On which Input/Output state will this rule be triggered.</td>
 
         <td>On which Input/Output state will this rule be triggered.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td><span style="color:red">ADC:</span> Input/Output name</td>
+
         <td><span style="color:red">Analog Current Loop (6,9), Analog Input (6,9):</span> State change</td>
         <td>ADC; default: <b>ADC</b></td>
+
        <td>In range {{!}} Out of range {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
         <td><span style="color:blue">Relay (5,10):</span> State change</td>
 +
        <td>Open {{!}} Closed {{!}} Both; default: <b>Both</b></td>
 +
        <td>On which Input/Output state will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:red">Analog Current Loop (7), Analog Input (7):</span> Min voltage</td>
 +
        <td>positive float; default: <b>none</b></td>
 +
        <td>At which minimum voltage value will this rule be triggered.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color:red">Analog Current Loop (7), Analog Input (7):</span> Max voltage</td>
 +
        <td>positive float; default: <b>none</b></td>
 +
        <td>At which maximum voltage value will this rule be triggered. Must be higher than Min voltage.</td>
 +
    </tr>
 +
|
 +
    <tr>
 +
        <td>Trigger</td>
 +
        <td>Configurable Input/Output (3) {{!}} Configurable Input/Output (4); default: <b>Configurable Input/Output (3)</b></td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td><span style="color:red">ADC:</span> Voltage</td>
+
         <td>State change</td>
         <td>positive float [0..40]; default: <b>none</b></td>
+
         <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
         <td>At which voltage value will this rule be triggered.</td>
+
         <td>On which Input/Output state will this rule be triggered.</td>
 
     </tr>
 
     </tr>
|TRB1 =
  −
    {{#ifeq:{{{name}}}|TRB141|
  −
        <tr>
  −
            <td>Input/Output type</td>
  −
            <td><span style="color:blue"><b>Input/Output</b></span> {{!}} <span style="color:dodgerblue"><b>Wet/Dry Input</b></span> {{!}} <span style="color:forestgreen"><b>Relay</b></span> {{!}} <span style="color:darkred"><b>4–20 mA Current Loop</b></span> {{!}} <span style="color:chocolate"><b>ADC</b></span>; default: <b>Input/Output</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:blue">Input/Output:</span> Input/Output name</td>
  −
            <td>Configurable Input/Output(3) {{!}} Configurable Input/Output(4); default: <b>Configurable Input/Output(3)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:blue">Input/Output:</span> State change</td>
  −
            <td>High level {{!}} Low level {{!}} Both; default: <b>High level</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:dodgerblue">Wet/Dry Input:</span> Input/Output name</td>
  −
            <td>Wet/Dry Input(1) {{!}} Wet/Dry Input(2); default: <b>Wet/Dry Input(1)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:dodgerblue">Wet/Dry Input:</span> State change</td>
  −
            <td>Rising {{!}} Falling {{!}} Both; default: <b>Rising</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:forestgreen">Relay:</span> Input/Output name</td>
  −
            <td>Relay(3,4,5) {{!}} Latching relay(11,12,13); default: <b>Relay(3,4,5)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:forestgreen">Relay:</span> State change</td>
  −
            <td>Open {{!}} Closed {{!}} Both; default: <b>Open</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Input/Output name</td>
  −
            <td>4–20 mA Current Loop; default: <b>4–20 mA Current Loop</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Voltage</td>
  −
            <td>positive float [0..40]; default: <b>none</b></td>
  −
            <td>At which voltage value will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:chocolate">ADC:</span> Input/Output name</td>
  −
            <td>ADC; default: <b>ADC</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:chocolate">ADC:</span> Voltage</td>
  −
            <td>positive float [0..40]; default: <b>none</b></td>
  −
            <td>At which voltage value will this rule be triggered.</td>
  −
        </tr>
  −
    |
  −
        <tr>
  −
            <td>Input/Output type</td>
  −
            <td>Input/Output; default: <b>Input/Output</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>Input/Output name</td>
  −
            <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>State change</td>
  −
            <td>High level {{!}} Low level {{!}} Both; default: <b>High level</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>}}
  −
|RUT36X =
  −
        <tr>
  −
            <td>Input/Output type</td>
  −
            <td>Input/Output; default: <b>Input/Output</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>Input/Output name</td>
  −
            <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>State change</td>
  −
            <td>High level {{!}} Low level {{!}} Both; default: <b>High level</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
|RUT9 =
  −
    {{#ifeq:{{{name}}}|RUT955|
  −
        <tr>
  −
            <td>Input/Output type</td>
  −
            <td><span style="color:blue">Input/Output</span> {{!}} <span style="color:forestgreen"><b>Relay</b></span> {{!}} <span style="color:darkred"><b>4–20 mA Current Loop</b></span> {{!}} <span style="color:chocolate">ADC</span>; default: <b>Input/Output</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:blue">Input/Output:</span> Input/Output name</td>
  −
            <td>Input (3) {{!}} Input (1) {{!}} Output(4) {{!}} Isolated Output (3,4,8) {{!}} Isolate Input (2,7); default: <b>Input (3)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:blue">Input/Output:</span> State change</td>
  −
            <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:forestgreen">Relay:</span> Input/Output name</td>
  −
            <td>Relay(5,10); default: <b>Relay(5,10)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:forestgreen">Relay:</span> State change</td>
  −
            <td>Open {{!}} Closed {{!}} Both; default: <b>Open</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Input/Output name</td>
  −
            <td>Analog Current Loop (6,9); default: <b>Analog Current Loop (6,9)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Voltage</td>
  −
            <td>positive float [0..40]; default: <b>none</b></td>
  −
            <td>At which voltage value will this rule be triggered.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:chocolate">ADC:</span> Input/Output name</td>
  −
            <td>Analog Input (6,9); default: <b>Analog Input (6,9)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td><span style="color:chocolate">ADC:</span> Voltage</td>
  −
            <td>positive float [0..40]; default: <b>none</b></td>
  −
            <td>At which voltage value will this rule be triggered.</td>
  −
        </tr>
  −
    |
  −
        <tr>
  −
            <td>Input/Output type</td>
  −
            <td>Input/Output; default: <b>Input/Output</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>Input/Output name</td>
  −
            <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
  −
            <td>Which type of Inputs and Outputs to use in this rule.</td>
  −
        </tr>
  −
        <tr>
  −
            <td>State change</td>
  −
            <td>High level {{!}} Low level {{!}} Both; default: <b>Both</b></td>
  −
            <td>On which Input/Output state will this rule be triggered.</td>
  −
        </tr>
   
     |}}
 
     |}}
 
}}
 
}}