| The <b>Modbus Serial Client</b> page is used to configure the device as a Modbus RTU Client. Modbus RTU (remote terminal unit) is a serial communication protocol mainly used in communication via serial interfaces. | | The <b>Modbus Serial Client</b> page is used to configure the device as a Modbus RTU Client. Modbus RTU (remote terminal unit) is a serial communication protocol mainly used in communication via serial interfaces. |
| | | |
| + | [[File:Networking_rutos_manual_modbus_modbus_serial_client.png|border|class=tlt-border]] |
| <!--<u><b>Note:</b> Modbus Serial Client is additional software that can be installed from the <b>Services → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u>--> | | <!--<u><b>Note:</b> Modbus Serial Client is additional software that can be installed from the <b>Services → [[{{{name}}} Package Manager|Package Manager]]</b> page.</u>--> |
| | | |
Line 570: |
Line 571: |
| This section is used to configure the Modbus Serial Client's server device interface settings. | | This section is used to configure the Modbus Serial Client's server device interface settings. |
| | | |
− | [[File:Networking_rutos_manual_modbus_modbus_serial_master_device_configuration_rs_device_modbus_master_configuration_v1_{{#ifeq:{{#expr: {{{rs232}}} or {{{usb}}}}} |1|1|0}}.png|border|class=tlt-border]] | + | [[File:Networking_rutos_manual_modbus_modbus_serial_client_device_configuration_rs_device_modbus_client_configuration_v1_{{#ifeq:{{#expr: {{{rs232}}} or {{{usb}}}}} |1|1|0}}.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 810: |
Line 811: |
| <td>Function code</td> | | <td>Function code</td> |
| <td>Read Coil Status (1) {{!}} Read Input Status (2) {{!}} Read Holding Registers (3) {{!}} Read Input Registers (4); default: <b>Read Coil Status (1)</b></td> | | <td>Read Coil Status (1) {{!}} Read Input Status (2) {{!}} Read Holding Registers (3) {{!}} Read Input Registers (4); default: <b>Read Coil Status (1)</b></td> |
− | <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Client (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#Slave_Device_Configuration|Server Device Configuration]].</td> | + | <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Client (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#Server_Device_Configuration|Server Device Configuration]].</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
Line 1,111: |
Line 1,112: |
| <td>Function code</td> | | <td>Function code</td> |
| <td>Read Coil Status (1) {{!}} Read Input Status (2) {{!}} Read Holding Registers (3) {{!}} Read Input Registers (4); default: <b>Read Coil Status (1)</b></td> | | <td>Read Coil Status (1) {{!}} Read Input Status (2) {{!}} Read Holding Registers (3) {{!}} Read Input Registers (4); default: <b>Read Coil Status (1)</b></td> |
− | <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Client (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#Slave_Device_Configuration|Server Device Configuration]].</td> | + | <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Client (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#Server_Device_Configuration|Server Device Configuration]].</td> |