Created page with "==2023.01.10: MAC address range change == Starting from Q2 2024, RUT901 routers will be manufactured with updated MAIN and RF board revisions. {| class="wikitable" |+ ! cols..."
==2023.01.10: MAC address range change ==

Starting from Q2 2024, RUT901 routers will be manufactured with updated MAIN and RF board revisions.

{| class="wikitable"
|+
! colspan="2" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" |Hardware change
|-
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 908px; text-align: left; background: white;" | Starting from Q2 2024, RUT901 routers will be manufactured with updated MAIN and RF board revisions. The following are the detailed updates made to the MAIN and RF boards:
* Added new USB HUB
* Added new USB-UART ICs - CH343 and CH9102
* Added new ADC - TLA2021
* SIM presence signals to SoC GPIO
* Added option to have SD card support
* Added shift register clearing circuitry
* Added pull-down resistors on pins to solve a problems might arise while shift registers are in tri-state high z state
* Removed 3.3V DC-DC. Now VIN -> 3.8V (MPS-AOZ) -> 3.3V (BL8028)
* Added more SIM switch options
* Added PG from MPS to USB current protection EN
* Added new EDGE footprint
* Removed 3.8V DCDC from RF board. 3.8V DCDC in on MAIN now

Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q2, 2024. During this period, your shipments of RUT901 may consist of either the current packaging or the new one described above.
|-
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" | Hardware design improvements
|-
|}

{| class="wikitable"
|+
! style="text-align: left; background: white;" colspan="3" | Affected products information
|-
| style="width: 221px; text-align: left; background: white;" | Model
| style="width: 448px; text-align: left; background: white;" | Affected order codes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
| style="text-align: left; background: white;" | RUT901
| style="text-align: left; background: white;" | RUT901 *****
| style="text-align: left; background: white;" | No changes
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | Q2 2024
|-
|}

{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |Device behaviour might change due to hardware changes. All RUT901 devices manufactured with new hardware revision, will require firmware version RUT9_R_00.07.XX.
|-
| style="text-align: left; background: white;" | Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |
Firmware downloads for the device can be found [[RUT901_Firmware_Downloads|here]].
For more detailed information please contact your sales representative.
|-
|}

{| class="wikitable"
|+
! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt
|-
| style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
|-
|}

To download the pdf version of this notification, [[Media:PCN All Products 2023 02 13 EN DPC v1.pdf|click here]].