TSW040 power consumption values in different states of operation are represented in the table(s) below:<br><br>
<table class="nd-othertables_3">
<tr style="font-weight:bold">
<th width=800>Test type</th>
<th width=150><center>Current (mA)</center></th>
<th width=170><center>Power consumption (W)</center></th>
</tr>
<tr>
<td>Idle (9 V)</td>
<td><center><b>27</b></center></td>
<td><center><b>0.24</b></center></td>
</tr>
<tr>
<td>Idle (12 V)</td>
<td><center><b>22</b></center></td>
<td><center><b>0.26</b></center></td>
</tr>
<tr>
<td>Idle (24 V)</td>
<td><center><b>13</b></center></td>
<td><center><b>0.31</b></center></td>
</tr>
<tr>
<td>Idle (44 V)</td>
<td><center><b>18</b></center></td>
<td><center><b>0.79</b></center></td>
</tr>
<tr>
<td>Idle (54 V)</td>
<td><center><b>17</b></center></td>
<td><center><b>0.92</b></center></td>
</tr>
<tr>
<td>Idle (57 V)</td>
<td><center><b>17</b></center></td>
<td><center><b>0.97</b></center></td>
</tr>
</table>


<table class="nd-othertables_3">
<tr style="font-weight:bold">
<th width=800>Test type</th>
<th width=150><center>Current (mA)</center></th>
<th width=170><center>Power consumption (W)</center></th>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (9 V)</td>
<td><center><b>50</b></center></td>
<td><center><b>0.45</b></center></td>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td>
<td><center><b>39</b></center></td>
<td><center><b>0.47</b></center></td>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td>
<td><center><b>22</b></center></td>
<td><center><b>0.53</b></center></td>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
<td><center><b>23</b></center></td>
<td><center><b>1.01</b></center></td>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (54 V)</td>
<td><center><b>21</b></center></td>
<td><center><b>1.13</b></center></td>
</tr>
<tr>
<td>2 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
<td><center><b>21</b></center></td>
<td><center><b>1.2</b></center></td>
</tr>
</table>


<table class="nd-othertables_3">
<tr style="font-weight:bold">
<th width=800>Test type</th>
<th width=150><center>Current (mA)</center></th>
<th width=170><center>Power consumption (W)</center></th>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (9 V)</td>
<td><center><b>113</b></center></td>
<td><center><b>1.02</b></center></td>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (12 V)</td>
<td><center><b>87</b></center></td>
<td><center><b>1.04</b></center></td>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (24 V)</td>
<td><center><b>47</b></center></td>
<td><center><b>1.13</b></center></td>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (44 V)</td>
<td><center><b>38</b></center></td>
<td><center><b>1.67</b></center></td>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (54 V)</td>
<td><center><b>33</b></center></td>
<td><center><b>1.78</b></center></td>
</tr>
<tr>
<td>8 LAN devices connected + heavy data traffic<sup><small>1</small></sup> (57 V)</td>
<td><center><b>33</b></center></td>
<td><center><b>1.88</b></center></td>
</tr>
</table>

<table class="nd-othertables_3">
<tr style="font-weight:bold">
<th width=800>Test type</th>
<th width=150><center>Current (mA)</center></th>
<th width=170><center>Power consumption (W)</center></th>
</tr>
<tr>
<td>Max load<sup><small>2</small></sup> (54 V)</td>
<td><center><b>2485</b></center></td>
<td><center><b>134.19</b></center></td>
</tr>
</table>


<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf.</small> <br>
<small><sup><small>2</small></sup> - 4 PoE devices 2 (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic, 4 PoE dummy loads connected (30 W each).</small> <br>
<small>Power consumption may differ due to connected devices, testing environment and conditions.</small>