==Configuring Modbus serial master== | ==Configuring Modbus serial master== | ||
Open router’s WebUI, navigate to '''Services > | Open router’s WebUI, navigate to '''Services → Modbus → Modbus Serial Client''' and in Serial Device configuratio section '''add new instance''' by entering a name, selecting '''rs232''' and pressing [[File:Add Button.png|60x90px]] button. In the newly opened Device Configuration window configure everything as follows: | ||
<table class="nd-othertables_2"> | |||
<tr> | |||
<th width=330; style="border-bottom: 1px solid white;></th> | |||
<th width=800; style="border-bottom: 1px solid white"; rowspan=2>[[File:Modbus Serial RUT955 1.png|border|class=tlt-border|755x406px|right]]</th> | |||
</tr> | |||
<tr> | |||
<td style="border-bottom: 4px solid white> | |||
# '''Enable''' instance; | |||
# Select '''Baud rate''' (9600, it must match slave‘s baud rate); | |||
# Select '''Parity''' (Even); | |||
# Press [[File:Networking save apply button fw76 v1.png|100x35px]] button. | |||
</td> | |||
</tr> | |||
</table> | |||
[[File:Modbus_serial_rut955_1.png|border|class=tlt-border|1100x700px]] | [[File:Modbus_serial_rut955_1.png|border|class=tlt-border|1100x700px]] | ||
Now create '''RS232 slave''' by writing a name, pressing '''Add''' button. It should appear like in the example and then press '''Edit'''. | Now create '''RS232 slave''' by writing a name, pressing '''Add''' button. It should appear like in the example and then press '''Edit'''. |