Line 148: | Line 148: | ||
<td>Function</td> | <td>Function</td> | ||
<td>1 | 2 | 3 | 4 | 5 | 6 | 15 | 16; Default: <b>3</b></td> | <td>1 | 2 | 3 | 4 | 5 | 6 | 15 | 16; Default: <b>3</b></td> | ||
<td> | <td>A function code specifies the type of register being addressed by a Modbus request. The codes represent these functions:<br> | ||
<ul> | <ul> | ||
<li><b>1</b> - | <li><b>1</b> - read Coil Status</li> | ||
<li><b>2</b> - | <li><b>2</b> - read Input Status</li> | ||
<li><b>3</b> - | <li><b>3</b> - read Holding Registers</li> | ||
<li><b>4</b> - | <li><b>4</b> - read Input Registers</li> | ||
<li><b>5</b> - | <li><b>5</b> - force Single Coil</li> | ||
<li><b>6</b> - | <li><b>6</b> - preset Single Register</li> | ||
<li><b>15</b> - | <li><b>15</b> - force Multiple Coils</li> | ||
<li><b>16</b> - | <li><b>16</b> - force Multiple Registers</li> | ||
</ul> | </ul> | ||
</td> | </td> | ||
Line 195: | Line 195: | ||
===Alarm configuration=== | ===Alarm configuration=== | ||
---- | ---- | ||
<b>Alarms</b> are way of | <b>Alarms</b> are way of setting up automated actions when some Modbus values meet user specified conditions. The figure below is an example of the <b>Alarm configuration</b> page and the table below provides information on fields that it contains: | ||
[[File:{{{file_alarms}}}]] | [[File:{{{file_alarms}}}]] | ||
Line 213: | Line 213: | ||
<td>Function code</td> | <td>Function code</td> | ||
<td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4); Default: <b>Read Coil Status (1)</b></td> | <td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4); Default: <b>Read Coil Status (1)</b></td> | ||
<td></td> | <td>Modbus function used in Modbus request</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Register</td> | <td>Register</td> | ||
<td>integer [0..65535]; Default: <b>none</b></td> | <td>integer [0..65535]; Default: <b>none</b></td> | ||
<td></td> | <td>Number of the modbus coil/input/holding register/input register that will be read</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Condition</td> | <td>Condition</td> | ||
<td>More than | Less than | Equal to | Not Equal to; Default: <b>Equal to</b></td> | <td>More than | Less than | Equal to | Not Equal to; Default: <b>Equal to</b></td> | ||
<td></td> | <td>When a value is obtained it will be compared against the value specified in the following field. The comparisson will be made in acordance with the condition specified in this field</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Value</td> | <td>Value</td> | ||
<td>various; Default: <b>none</b></td> | <td>various; Default: <b>none</b></td> | ||
<td></td> | <td>The value against which the read data will be compared</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Action</td> | <td>Action</td> | ||
<td>SMS | Trigger output | Modbus Request; Default: <b>SMS</b></td> | <td>SMS | Trigger output | Modbus Request; Default: <b>SMS</b></td> | ||
<td></td> | <td>Action that will be taken if the condition is met. Possible actions: | ||
<ul> | |||
<li><b>SMS</b> - sends and SMS message to a specified recipient(s)</li> | |||
<li><b>Trigger output</b> - changes the state of a specified output(s)</li> | |||
<li><b>Modbus Request</b> - sends a Modbus request to a specified slave</li> | |||
</ul> | |||
</td> | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 243: | Line 249: | ||
<td><span style="color: #0054a6;">SMS: Phone number</span></td> | <td><span style="color: #0054a6;">SMS: Phone number</span></td> | ||
<td>phone number; Default: <b>none</b></td> | <td>phone number; Default: <b>none</b></td> | ||
<td> | <td>Recipient's phone number</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td><span style="color: red;">Trigger output: Output</span></td> | <td><span style="color: red;">Trigger output: Output</span></td> | ||
<td>Open collector output | Relay output | Both; Default: <b>Open collector output</b></td> | <td>Open collector output | Relay output | Both; Default: <b>Open collector output</b></td> | ||
<td>Which output will be triggered</td> | <td>Which output(s) will be triggered</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 258: | Line 264: | ||
<td><span style="color: purple;">Modbus Request: IP address</span></td> | <td><span style="color: purple;">Modbus Request: IP address</span></td> | ||
<td>ip | host; Default: <b>none</b></td> | <td>ip | host; Default: <b>none</b></td> | ||
<td>Modbus slave's address</td> | <td>Modbus slave's IP address</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 278: | Line 284: | ||
<td><span style="color: purple;">Modbus Request: Modbus function</span></td> | <td><span style="color: purple;">Modbus Request: Modbus function</span></td> | ||
<td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4) | Force Single Coil (5) | Preset Single Register (6) | Force Multiple Coils (15) | Force Multiple Registers (16); Default: <b>Force Single Coil (5)</b></td> | <td>Read Coil Status (1) | Read Input Status (2) | Read Holding Registers (3) | Read Input Registers (4) | Force Single Coil (5) | Preset Single Register (6) | Force Multiple Coils (15) | Force Multiple Registers (16); Default: <b>Force Single Coil (5)</b></td> | ||
<td></td> | <td>A function code specifies the type of register being addressed by a Modbus request</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 288: | Line 294: | ||
<td><span style="color: purple;">Modbus Request: Number of registers</span></td> | <td><span style="color: purple;">Modbus Request: Number of registers</span></td> | ||
<td>integer [0..65535]; Default: <b>none</b></td> | <td>integer [0..65535]; Default: <b>none</b></td> | ||
<td></td> | <td>The number of registers that will be read from the first register</td> | ||
</tr> | </tr> | ||
</table> | </table> |