Line 744: |
Line 744: |
| | | |
| The Change mobile data settings rule is exceptional to most of the other rules as it does not perform a single action like turning specific services On/Off or getting status updates. It designed to change mobile data settings and it's '''SMS text''' can't be described by a single string because the message depends on what configurations you want to change. For example, you can send a message that will change your APN only, you can send a message that will change APN and mobile service mode, or even a message that will change every single mobile setting. | | The Change mobile data settings rule is exceptional to most of the other rules as it does not perform a single action like turning specific services On/Off or getting status updates. It designed to change mobile data settings and it's '''SMS text''' can't be described by a single string because the message depends on what configurations you want to change. For example, you can send a message that will change your APN only, you can send a message that will change APN and mobile service mode, or even a message that will change every single mobile setting. |
| + | |
| + | {| class="wikitable" |
| + | |+ Change mobile data settings |
| + | ! style="width: 250px; background: black; color: white;" | Field name |
| + | ! style="width: 500px; background: black; color: white;" | Explanation |
| + | ! style="width: 950px; background: black; color: white;" | Notes |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Enable |
| + | | style="vertical-align: top;" | This check box will enable or disable the Switch output function |
| + | | style="vertical-align: top;" | Allows output control via SMS |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Action |
| + | | style="vertical-align: top;" | The action to be performed when this rule is met. |
| + | | Turn output On or Off |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Active timeout |
| + | | style="vertical-align: top;" | Make the rule active for a specific time; |
| + | format: '''seconds''' |
| + | | '''Example:''' if you configure a rule to turn a specific output on and set a 30 s timeout, the output will be activated once the router receives the SMS messages and then it will deactivated after a period of 30 s |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | SMS text |
| + | | style="vertical-align: top;" | SMS text that will trigger the rule. In this case, switch output on/off |
| + | | style="vertical-align: top;" | SMS text can contain letters, numbers, spaces and special symbols. Capital letters also matter |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Authorization method |
| + | | style="vertical-align: top;" | What kind of authorization to use for SIM management |
| + | | style="vertical-align: top;" | Possible values: |
| + | No authorization {{!}} By serial {{!}} By router admin password; Default: '''By router admin password''' |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Allowed users |
| + | | style="vertical-align: top;" | White list of allowed users |
| + | | style="vertical-align: top;" | Possible values: |
| + | From all numbers {{!}} From group {{!}} From single number; Default: '''From all numbers''' |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Output type |
| + | | style="vertical-align: top;" | Which output will be activated |
| + | | style="vertical-align: top;" | Possible values: |
| + | Digital OC output {{!}} Relay output; Default: '''Digital OC output''' |
| + | |- |
| + | |} |