Changes

Line 113: Line 113:  
       <dl>
 
       <dl>
 
           <dt>Issue</dt>
 
           <dt>Issue</dt>
           <dd>After connecting more than two device {{{name}}} all connected PoE devices lost power</dd>
+
           <dd>All PoE devices and switch lost power after connecting more than two device to {{{name}}}</dd>
 
           <dt>Solution</dt>
 
           <dt>Solution</dt>
           <dd>{{{name}}} supports 802.3at standard, were each port can supply up to 30 W of power at PSE with total power budget of 120 W per all 4 ports. Standard PSU, which comes in the box with {{{name}}}, provides ~65 W power and limits power budget to ~60 W. If connected to PoE all connected devices to PoE ports combined required more that 60 W of power, PSU was overloaded and turned itself off. If full 120 W power budget is necessary, {{{name}}} switch must be powered with PSU which can provide 130 W po at 44 VDC or higher voltages</dd>
+
           <dd>{{{name}}} supports 802.3at standard, were each port can supply up to 30 W of power at PSE with total power budget of 120 W per all 4 ports. Standard PSU, which comes in the box with {{{name}}}, provides ~65 W power and limits power budget to ~60 W. If all connected devices to PoE ports combined required more that 60 W of power, PSU was overloaded and turned itself off.<br>If full 120 W power budget is necessary, {{{name}}} switch must be powered with PSU which can provide 130 W po at 44 VDC or higher voltages</dd>
 
       </dl>
 
       </dl>
 
     </li>
 
     </li>

Navigation menu