Changes

Line 55: Line 55:  
|-
 
|-
 
! 3  
 
! 3  
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.
+
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.<br />Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. || For a Spray Nozzle:<br />
Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. || For a Spray Nozzle:<br />
   
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<br />
 
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<br />
 
Water volume: 10&nbsp;litres per minute<br />
 
Water volume: 10&nbsp;litres per minute<br />