====RS232 Slave Devices List====
 
====RS232 Slave Devices List====
 
----
 
----
The <b>RS232 Slave Devices List</b> section is used to configure the parameters of Modbus RUT slaves that the Master (this {{{name}}} device) will be querying with requests.
+
The <b>RS232 Slave Devices List</b> section is used to configure the parameters of Modbus RTU slaves that the Master (this {{{name}}} device) will be querying with requests.
   −
The list is empty by default. In order to create a new slave device configuration, click the 'Add' button.
+
The list is empty by default. In order to create a new slave device configuration, click the 'Add' button. A new configuration window should pop up.
    
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs232_slave_devices_list_add_button.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs232_slave_devices_list_add_button.png|border|class=tlt-border]]
  −
Then click the 'Edit' button next to the newly added slave device in order to begin configuration.
  −
  −
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs232_slave_devices_list_edit_button.png|border|class=tlt-border]]
      
=====RS232 Slave Device Configuration=====
 
=====RS232 Slave Device Configuration=====
Line 543: Line 539:     
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_add_button.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_add_button.png|border|class=tlt-border]]
  −
Then click the 'Edit' button next to the newly created Alarm to configuration.
  −
  −
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_edit_button.png|border|class=tlt-border]]
      
After this you should be redirected to that Alarm's configuration page which should look similar to this:
 
After this you should be redirected to that Alarm's configuration page which should look similar to this:
Line 566: Line 558:  
         <td>Function code</td>
 
         <td>Function code</td>
 
         <td>Read Coil Status (1) <nowiki>|</nowiki> Read Input Status (2) <nowiki>|</nowiki> Read Holding Registers (3) <nowiki>|</nowiki> Read Input Registers (4); default: <b>Read Coil Status (1)</b></td>
 
         <td>Read Coil Status (1) <nowiki>|</nowiki> Read Input Status (2) <nowiki>|</nowiki> Read Holding Registers (3) <nowiki>|</nowiki> Read Input Registers (4); default: <b>Read Coil Status (1)</b></td>
         <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Master (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#RS485_Slave_Device_Configuration|RS485 Slave Device Configuration]].</td>
+
         <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Master (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#RS232_Slave_Device_Configuration|RS232 Slave Device Configuration]].</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 707: Line 699:  
====RS485 Slave Devices List====
 
====RS485 Slave Devices List====
 
----
 
----
The <b>RS485 Slave Devices List</b> section is used to configure the parameters of Modbus RUT slaves that the Master (this {{{name}}} device) will be querying with requests.
+
The <b>RS485 Slave Devices List</b> section is used to configure the parameters of Modbus RTU slaves that the Master (this {{{name}}} device) will be querying with requests.
   −
The list is empty by default. In order to create a new slave device configuration, click the 'Add' button.
+
The list is empty by default. In order to create a new slave device configuration, click the 'Add' button. A new configuration window should pop up.
    
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs485_slave_devices_list_add_button.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs485_slave_devices_list_add_button.png|border|class=tlt-border]]
  −
Then click the 'Edit' button next to the newly added slave device in order to begin configuration.
  −
  −
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs485_slave_devices_list_edit_button.png|border|class=tlt-border]]
      
=====RS485 Slave Device Configuration=====
 
=====RS485 Slave Device Configuration=====
Line 833: Line 821:     
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_add_button.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_add_button.png|border|class=tlt-border]]
  −
Then click the 'Edit' button next to the newly created Alarm to configuration.
  −
  −
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_edit_button.png|border|class=tlt-border]]
      
After this you should be redirected to that Alarm's configuration page which should look similar to this:
 
After this you should be redirected to that Alarm's configuration page which should look similar to this:
Line 940: Line 924:  
</table>
 
</table>
 
|}}
 
|}}
 +
 +
{{#ifeq: {{{console}}} | 1 |
 +
===Console===
 +
----
 +
This section is used to configure the Modbus Serial Master's <b>Console</b> serial interface settings. Refer to the figure and table below for information on Console configuration.
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_serial_master_console_configuration.png|border|class=tlt-border]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>Field</th>
 +
        <th>Value</th>
 +
        <th>Description</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Enabled</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Turns Modbus Serial Master configuration via RS232 on or off. Both this and RS232 from Services → [[{{{name}}} RS232|RS232]] cannot be enabled at the same time.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Baud rate</td>
 +
        <td>300 <nowiki>|</nowiki> 1200 <nowiki>|</nowiki> 2400 <nowiki>|</nowiki> 4800 <nowiki>|</nowiki> 9600 <nowiki>|</nowiki> 19200 <nowiki>|</nowiki> 38400 <nowiki>|</nowiki> 57600 <nowiki>|</nowiki> 115200 <nowiki>|</nowiki> 1000000; default: <b>115200</b></td>
 +
        <td>Serial data transmission rate (in bits per second).</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Data bits</td>
 +
        <td>5 <nowiki>|</nowiki> 6 <nowiki>|</nowiki> 7 <nowiki>|</nowiki> 8; default: <b>8</b></td>
 +
        <td>Number of data bits for each character.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Parity</td>
 +
        <td>None <nowiki>|</nowiki> Even <nowiki>|</nowiki> Odd; default: <b>None</b></td>
 +
        <td>In serial transmission, parity is a method of detecting errors. An extra data bit is sent with each data character, arranged so that the number of 1 bits in each character, including the parity bit, is always odd or always even. If a byte is received with the wrong number of 1s, then it must have been corrupted. However, an even number of errors can pass the parity check.
 +
            <ul>
 +
                <li><b>None</b> (<b>N</b>) - no parity method is used.</li>
 +
                <li><b>Odd</b> (<b>O</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be odd.</li>
 +
                <li><b>Even</b> (<b>E</b>) - the parity bit is set so that the number of "logical ones (1s)" has to be even.</li>
 +
            </ul>
 +
        </td>
 +
    </tr>
 +
    <tr>
 +
        <td>Stop bits</td>
 +
        <td>1 <nowiki>|</nowiki> 2; default: <b>1</b></td>
 +
        <td>Stop bits sent at the end of every character allow the receiving signal hardware to detect the end of a character and to resynchronise with the character stream. Electronic devices usually use one stop bit. Two stop bits are required if slow electromechanical devices are used.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Flow control</td>
 +
        <td>None <nowiki>|</nowiki> RTS/CTS <nowiki>|</nowiki> Xon/Xoff; default: <b>None</b></td>
 +
        <td>In many circumstances a transmitter might be able to send data faster than the receiver is able to process it. To cope with this, serial lines often incorporate a "handshaking" method, usually distinguished between hardware and software handshaking.
 +
            <ul>
 +
                <li><b>RTS/CTS</b> - hardware handshaking. RTS and CTS are turned OFF and ON from alternate ends to control data flow, for instance when a buffer is almost full.</li>
 +
                <li><b>Xon/Xoff</b> - software handshaking. The Xon and Xoff characters are sent by the receiver to the sender to control when the sender will send data, i.e., these characters go in the opposite direction to the data being sent. The circuit starts in the "sending allowed" state. When the receiver's buffers approach capacity, the receiver sends the Xoff character to tell the sender to stop sending data. Later, after the receiver has emptied its buffers, it sends an Xon character to tell the sender to resume transmission.</li>
 +
            </ul>
 +
        </td>
 +
    </tr>
 +
</table>
 +
 +
====Console Slave Devices List====
 +
----
 +
The <b>Console Slave Devices List</b> section is used to configure the parameters of Modbus RTU slaves that the Master (this {{{name}}} device) will be querying with requests.
 +
 +
The list is empty by default. In order to create a new slave device configuration, click the 'Add' button. A new configuration window should pop up.
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_serial_master_console_slave_devices_list_add_button.png|border|class=tlt-border]]
 +
 +
=====Slave Device Configuration=====
 +
----
 +
The <b>Slave Device Configuration</b> section is used to configure the parameters of Modbus RTU slaves that the Master (this {{{name}}} device) will be querying with requests. The figure below is an example of the Slave Device Configuration and the table below provides information on the fields contained in that section:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_serial_master_rs232_slave_device_configuration.png|border|class=tlt-border]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>Field</th>
 +
        <th>Value</th>
 +
        <th>Description</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Enabled</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Turns communication with the slave device on or off.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Name</td>
 +
        <td>string; default: <b>none</b></td>
 +
        <td>Slave device's name, used for easier management purposes.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Slave ID</td>
 +
        <td>integer [0..255]; default: <b>none</b></td>
 +
        <td>Slave ID. Each slave in a network is assigned a unique identifier ranging from 1 to 255. When the master requests data from a slave, the first byte it sends is the Slave ID. When set to 0, the slave will respond to requests addressed to any ID.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Period</td>
 +
        <td>integer [1..86400]; default: <b>60</b></td>
 +
        <td>Interval at which requests are sent to the slave device.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Timeout</td>
 +
        <td>integer [1..30]; default: <b>5</b></td>
 +
        <td>Maximum response wait time.</td>
 +
    </tr>
 +
</table>
 +
=====Requests Configuration=====
 +
----
 +
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device.
 +
 +
<span style="color:red"> <b>Note: </b></span> Modbus Serial Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field.
 +
 +
The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_tcp_master_requests_configuration_add_new_instance.png|border|class=tlt-border]]
 +
 +
The new Request Configuration should become visible in the list:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_tcp_master_requests_configuration.png|border|class=tlt-border]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>Field</th>
 +
        <th>Value</th>
 +
        <th>Description</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Name</td>
 +
        <td>string; default: <b>Unnamed</b></td>
 +
        <td>Name of this Request Configuration. Used for easier management purposes.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Data type</td>
 +
        <td>8bit INT <nowiki>|</nowiki> 8bit UINT <nowiki>|</nowiki> 16bit INT, high byte first <nowiki>|</nowiki> 16bit INT, low byte first <nowiki>|</nowiki> 16bit UINT, high byte first <nowiki>|</nowiki> 16bit UINT, low byte first <nowiki>|</nowiki> 32bit float, Byte order 1,2,3,4 <nowiki>|</nowiki> 32bit float, Byte order 4,3,2,1 <nowiki>|</nowiki> 32bit float, Byte order 2,1,4,3 <nowiki>|</nowiki> 32bit float, Byte order 3,4,1,2; default: <b>16bit INT, high byte first</b></td>
 +
        <td>Defines how read data will be stored.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Function</td>
 +
        <td>Read coils (1) <nowiki>|</nowiki> Read input coils (2) <nowiki>|</nowiki> Read holding registers (3) <nowiki>|</nowiki> Read input registers (4) <nowiki>|</nowiki> Set single coil (5) <nowiki>|</nowiki> Set single coil register (6) <nowiki>|</nowiki> Set multiple coils (15) <nowiki>|</nowiki> Set multiple holding registers (16); default: <b>Read holding registers (3)</b></td>
 +
        <td>Specifies the type of register being addressed by a Modbus request.
 +
        </td>
 +
    </tr>
 +
    <tr>
 +
        <td>First Register</td>
 +
        <td>integer [0..65535]; default: <b>1</b></td>
 +
        <td>First Modbus register from which data will be read.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Register Count / Values</td>
 +
        <td>integer [1..2000]; default: <b>1</b></td>
 +
        <td>Number of Modbus registers that will be read during the request.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>No Brackets</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Removes the starting and ending brackets from the request (only for read requests).</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Delete [ X ]</td>
 +
        <td>- (interactive button)</td>
 +
        <td>Deletes the request.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>off/on slider</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Turns the request on or off.</td>
 +
    </tr>
 +
</table>
 +
 +
<b>Additional note:</b> by default the newly added Request Configurations are turned off. You can use the on/off slider to the right of the Request Configuration to turn it on:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_tcp_master_requests_configuration_on_off_slider.png|border|class=tlt-border]]
 +
----
 +
After having configured a request, you should see a new 'Request Configuration Testing' section appear. It is used to check whether the configuration works correctly. Simply click the 'Test' button and a response should appear in the box below. A successful response to a test may look something like this:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_tcp_master_requests_configuration_testing.png|border|class=tlt-border]]
 +
 +
=====Modbus Master Alarms=====
 +
----
 +
<b>Alarms</b> are a way of setting up automated actions when some Modbus values meet user-defined conditions. When the Modbus Serial Master (this {{{name}}} device) requests some information from a slave device it compares that data to with the parameters set in an Alarm Configuration. If the comparison meets the specified condition (more than, less than, equal to, not equal to), the Master performs a user-specified action, for example, a Modbus write request or switching the state of an output.
 +
 +
The figure below is an example of the Modbus Master Alarms list. To create a new Alarm, click the 'Add' button.
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_add_button.png|border|class=tlt-border]]
 +
 +
After this you should be redirected to that Alarm's configuration page which should look similar to this:
 +
 +
[[File:Networking_rutos_manual_modbus_modbus_serial_master_modbus_master_alarms_alarm_configuration.png|border|class=tlt-border]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>Field</th>
 +
        <th>Value</th>
 +
        <th>Description</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Enabled</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Turns the alarm on or off.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Function code</td>
 +
        <td>Read Coil Status (1) <nowiki>|</nowiki> Read Input Status (2) <nowiki>|</nowiki> Read Holding Registers (3) <nowiki>|</nowiki> Read Input Registers (4); default: <b>Read Coil Status (1)</b></td>
 +
        <td>Modbus function used for this alarm's Modbus request. The Modbus TCP Master (this {{{name}}} device) perform this request as often as specified in the 'Period' field in [[#RS485_Slave_Device_Configuration|RS485 Slave Device Configuration]].</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Register</td>
 +
        <td>integer [1..65536]; default: <b>none</b></td>
 +
        <td>Number of the Modbus coil/input/holding-register/input-register to read from.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Condition</td>
 +
        <td>More than <nowiki>|</nowiki> Less than <nowiki>|</nowiki> Equal to <nowiki>|</nowiki> Not Equal to; default: <b>Equal to</b></td>
 +
        <td>When a value is obtained it will be compared against the value specified in the following field. The comparison will be made in accordance with the condition specified in this field.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Value</td>
 +
        <td>various; default: <b>none</b></td>
 +
        <td>The value against which the read data will be compared.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Value</td>
 +
        <td>integer [0..65535]; default: <b>none</b></td>
 +
        <td>The value against which the read data will be compared.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Action frequency</td>
 +
        <td>Every trigger <nowiki>|</nowiki> First trigger; default: <b>Every trigger</b></td>
 +
        <td>Describes how frequently the specified action will be taken.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Redundancy protection</td>
 +
        <td>off <nowiki>|</nowiki> on; default: <b>off</b></td>
 +
        <td>Protection against executing a configured action too often.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Redundancy protection period</td>
 +
        <td>integer [1..86400]; default: <b>none</b></td>
 +
        <td>Duration to activate redundancy protection for, measured in seconds. This field becomes visible only when 'Redundancy protection' is turned on.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Action</td>
 +
        <td>{{#ifeq:{{{mobile}}}|1|SMS {{!}}|}} MODBUS Write Request; default: <b>MODBUS Write Request</b></td>
 +
        <td>Action that will be taken if the condition is met. Possible actions:
 +
            <ul>{{#ifeq: {{{mobile}}} | 1 |
 +
                <li><b>SMS</b> - sends and SMS message to a specified recipient(s).</li>|}}
 +
                <li><b>Modbus Request</b> - sends a Modbus Write request to a specified slave.</li>
 +
            </ul>
 +
        </td>
 +
    </tr>{{#ifeq: {{{mobile}}} | 1 |
 +
    <tr>
 +
        <td><span style="color: #0054a6;">SMS: Message</span></td>
 +
        <td>string; default: <b>none</b></td>
 +
        <td>SMS message text.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color: #0054a6;">SMS: Phone number</span></td>
 +
        <td>phone number; default: <b>none</b></td>
 +
        <td>Recipient's phone number.</td>
 +
    </tr>|}}
 +
    <tr>
 +
        <td><span style="color: purple;">MODBUS Write Request: Timeout</span></td>
 +
        <td>integer [1..30]; default: <b>5</b></td>
 +
        <td>Maximum time to wait for a response.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color: purple;">MODBUS Write Request: ID</span></td>
 +
        <td>integer [1..255]; default: <b>none</b></td>
 +
        <td>Modbus slave ID.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color: purple;">MODBUS Write Request: Modbus function</span></td>
 +
        <td>Read Force Single Coil (5) <nowiki>|</nowiki> Preset Single Register (6) <nowiki>|</nowiki> Force Multiple Coils (15) <nowiki>|</nowiki> Force Multiple Registers (16); default: <b>Force Single Coil (5)</b></td>
 +
        <td>A function code specifies the type of register being addressed by a Modbus request.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color: purple;">MODBUS Write Request: First register</span></td>
 +
        <td>integer [0..65535]; default: <b>none</b></td>
 +
        <td>Begins reading from the register specified in this field.</td>
 +
    </tr>
 +
    <tr>
 +
        <td><span style="color: purple;">MODBUS Write Request: Values</span></td>
 +
        <td>integer [0..65535]; default: <b>none</b></td>
 +
        <td>Register/Coil values to be written (multiple values must be separated by space character).</td>
 +
    </tr>
 +
</table>
    