TRB160 Product Change Notifications

From Teltonika Networks Wiki
Main Page > TRB Gateways > TRB160 > TRB160 Product Change Notifications

Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).

This page stores information regarding changes to the TRB160 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).

2025.04.22: Transition to HTTPS protocol RutOS 7.15

With the release of RutOS version 7.15 in Q2 2025, TRB160 devices will disable the HTTP protocol and enable HTTPS Redirect by default to enhance WebUI and API communication security.

PCN Number: PCN_Transition_HTTPS_TRB160_2025_04_22
Change description
Change type RutOS Security Enhancement
Detailed description With the release of RutOS version 7.15 firmware, the device's WebUI and API default communication methods will change. The HTTP protocol will be changed to HTTPS (only) in default configuration for security reasons and complying with security standards. The "HTTPS Redirect" functionality will be enabled by default so all HTTP requests will be automatically redirected through the HTTPS channel.
Change reasons To enhance security measures and comply with security standards by eliminating unsecured HTTP protocol usage.
Affected products information
Model Affected order codes Order code changes
TRB160 All No changes
Upcoming change date Q2 2025
Change impact
Risk assessment
  • Users may receive a browser warning indicating that the connection is not secure due to the use of a self-signed certificate in HTTPS.
  • API users may experience issues depending on the tools they use to communicate with the API, as some may not support HTTPS, self-signed certificates or the tooling may have to be reconfigured to adapt to these changes.
Suggested implementation plan
  • Information included in this PCN will help adapt to the upcoming changes. URL1 URL2 For more detailed information, please contact your sales representative.
  • API users should update their tools and scripts to support HTTPS communication and handle self-signed certificates.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.

2025.02.25: Mobile and I/O POST/GET Service Removal with RutOS 7.14

With the release of RutOS version 7.14, support for the TRB160 POST/GET service will be discontinued to enhance security while maintaining device functionality through alternative methods.

PCN Number: PCN_RUTOS 7.14_POST_GET_Removal_TRB160_2025_02_25_EN
Change description
Change type Firmware change
Detailed description With the introduction of RutOS 7.14, the Mobile POST/GET and I/O POST/GET services will be removed from the firmware and will no longer be available in the package manager. These legacy services had security concerns, and their removal ensures a more robust security framework for the device. However, users will still be able to achieve the same functionalities using the device's API, which provides a more secure and efficient way to interact with the system.
Change reasons
  • Enhanced Security: Removing these services mitigates potential security risks and improves overall system integrity.
  • Improved API Support: Users can leverage the API for secure and flexible data handling without relying on deprecated methods.
  • The change aligns with modern security protocols and best practices in remote device management.
Affected products information
Model Affected order codes Order code changes
TRB160 TRB160 ****** No changes
Upcoming change date 2025 Q2, with the release of RutOS 7.14
Change impact
Risk assessment
  • Clients using Mobile POST/GET and I/O POST/GET services will need to transition to API-based methods.
  • Some automation processes relying on these legacy services may require reconfiguration
  • API documentation and support resources will be available to facilitate a smooth transition.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2025.02.24: Implementation of Read-Only System Files in RutOS 7.14

With the release of RutOS version 7.14 in Q2 2025, in TRB160 devices will implement read-only permissions for critical system files by default. The new read-only configuration ensures a more secure and stable environment, though it may affect those who perform non-standard operations.

PCN Number: PCN_read_only_system_TRB160_2025_02_24
Change description
Change type RutOS System Integrity Enhancement
Detailed description With the release of RutOS version 7.14, the device’s critical system files will become read-only by default. This prevents unauthorized or accidental modifications that could damage the system’s integrity. Standard users operating within typical parameters should not be affected, while those who rely on direct file alterations will need to adjust their workflows. Custom firmware options are expected to allow reverting to a more flexible configuration if required.
Change reasons To maintain system integrity, enhance reliability, and prevent unintended damage to core files.
Affected products information
Model Affected order codes Order code changes
TRB160 TRB160 ****** No changes
Upcoming change date Q2 2025
Change impact
Risk assessment
  • Customers performing direct system-level modifications may need to adjust their procedures.
  • Standard end-users, who do not rely on altering critical system files, are unlikely to be affected.
  • Custom firmware solutions can restore file-level flexibility if required.
Suggested implementation plan
  • Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
  • Review current workflows and identify any reliance on direct system file modifications. Consider using custom firmware builds if continued system-level customization is necessary.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.


2025.02.20: WebUI Mode Update with RutOS 7.13

With the release of RutOS version 7.13, TRB160 the WebUI will undergo changes to enhance user experience and accessibility.

PCN Number: PCN_RUTOS_CHANGE_TRB160_2025_02_20_EN
Change description
Change type Firmware change
Detailed description Previously, the WebUI provided two separate modes: Basic Mode and Advanced Mode. With the introduction of RutOS 7.13, these two modes will be merged into a unified interface, where users will have access to all settings within one mode.
Change reasons
  • Improved Usability: A single mode simplifies navigation and enhances user-friendliness.
  • Increased Accessibility: All essential settings remain available without needing to switch between modes.
  • Optimized User Experience: A streamlined design enhances efficiency and ease of use.
  • User-Driven Enhancement: This change is based on user feedback, aiming to create a more intuitive and accessible WebUI experience.
Affected products information
Model Affected order codes Order code changes
TRB160 TRB160 ****** No changes
Upcoming change date 2025 Q2, with the release of RutOS 7.13
Change impact
Risk assessment
  • Users accustomed to switching between Basic and Advanced Mode may require time to adapt to the unified interface.
  • Settings will now be presented in a single, continuous view rather than separated into different modes.
  • Minor learning curve for users transitioning from previous WebUI versions.
Suggested implementation plan
  • Review the unified WebUI mode and familiarize yourself with having all settings available.
  • Refer to the updated user documentation and support resources for guidance.

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.11.22: Device Housing - Engraving/Labeling changes

Starting from December 2024, TRB160 devices will be produced with top and bottoms stickers.

PCN Number: PCN_Housing_Engraving.Labeling_TRB160_2024.11.22_EN
Change description
Change type Visual Changes
Detailed description The device will be manufactured with top and bottom stickers instead of engravings due to the thickness of the paint coating on the housing. The information on the stickers will not be affected.

Please note that this change will be implemented gradually, throughout a 1-month transitional period starting from December, 2024. During this period, your shipments of TRB160 may consist of either the current design or the new one described above.

Change reasons Reducing the risk for client to receive lower quality engraving on the housing.
Affected products information
Model Affected order codes Order code changes
TRB160 TRB160 ***** No changes
Upcoming change date December 1st, 2024
Change impact
Risk assessment

No risk factors are associated with this change. Please note: this product change notification does not affect any previous TRB160 devices, except new TRB160 devices that will be manufactured with this change.

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.09.18: EAN Code Change

Starting from October 1st 2024, new order codes created will have their own unique EAN codes.

PCN Number: PCN_EAN_Code_Change_TRB160_2024.09.18_EN
Change description
Change type Logistics change
Detailed description The product identification system is being updated by assigning unique EAN codes to each new order code created from October 1st.
Change reasons Improving product traceability, inventory management, and logistics accuracy across ordering and distribution systems.
Affected products information
Model Affected order codes Order code changes
TRB160 TRB160 ***** No changes
Upcoming change date October 1st, 2024
Change impact
Risk assessment

Every order code, created after this change, will have its own unique EAN code. Therefore, it might cause the need to review inventory management and ordering processes.

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.