TSW304 Power Consumption
From Teltonika Networks Wiki
Main Page > TSW Switches > TSW304 > TSW304 Manual > TSW304 Power Consumption
Averaged TSW304 power consumption values in different states of operation are represented in the table(s) below:
Test type | Current (mA) | Power consumption (W) |
---|---|---|
Idle (9 V) | 28 | 0.25 |
Idle (12 V) | 22 | 0.26 |
Idle (24 V) | 11 | 0.26 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
2 LAN devices connected + heavy data traffic1 (9 V) | 103 | 0.92 |
2 LAN devices connected + heavy data traffic1 (12 V) | 78 | 0.93 |
2 LAN devices connected + heavy data traffic1 (24 V) | 40 | 0.96 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
3 LAN devices connected + heavy data traffic1 (9 V) | 143 | 1.28 |
3 LAN devices connected + heavy data traffic1 (12 V) | 108 | 1.29 |
3 LAN devices connected + heavy data traffic1 (24 V) | 54 | 1.29 |
Test type | Current (mA) | Power consumption (W) |
---|---|---|
4 LAN devices connected + heavy data traffic1 (9 V) | 158 | 1.42 |
4 LAN devices connected + heavy data traffic1 (12 V) | 119 | 1.42 |
4 LAN devices connected + heavy data traffic1 (24 V) | 60 | 1.44 |
1 - Data streams between devices were created using iPerf.
Power consumption may differ due to testing environment and conditions.