Template:Networking trb2m manual input output status
Appearance
ioman.adc.adc0 - Analog input ioman.gpio.dio0 - Configurable input/output (PIN2) ioman.gpio.dio1 - Configurable input/output (PIN3) ioman.gpio.dio2 - Configurable input/output (PIN4)
Call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
{
"value": "0",
"direction": "out",
"bi_dir": true,
"invert_input": false
}
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- "direction": "in" means input state.
- "direction": "out" means output state.
- adc0 is analog input:
- "value": "0.54" means 0.54V.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}'
ubus call ioman.gpio.dio0 update '{"value":"1"}'
ubus call ioman.gpio.dio0 update '{"direction":"in"}'
ubus call ioman.gpio.dio0 update '{"direction":"out"}'