Line 62: |
Line 62: |
| Go back to the '''Slave configuration''' window and create '''Slave request''' by writing a name, pressing '''Add''' button. It should appear like in the example and then press '''Edit'''. | | Go back to the '''Slave configuration''' window and create '''Slave request''' by writing a name, pressing '''Add''' button. It should appear like in the example and then press '''Edit'''. |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_6_v1.png|border|class=tlt-border]] |
| | | |
| Then apply the following configuration. | | Then apply the following configuration. |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_7_v1.png|border|class=tlt-border]] |
| | | |
| # Check '''Enable'''. | | # Check '''Enable'''. |
Line 83: |
Line 83: |
| In the topology below you can find information on how the device and server are connected. | | In the topology below you can find information on how the device and server are connected. |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_8_v1.png|border|class=tlt-border]] |
| | | |
| There are many ways how you can create a server to which Modbus will send data to. In this example we are going to be using Windows 10 computer and Hercules app, which you can download [https://www.hw-group.com/product-version/hercules here], to create a test server. Download, install the app and apply the configuration below: | | There are many ways how you can create a server to which Modbus will send data to. In this example we are going to be using Windows 10 computer and Hercules app, which you can download [https://www.hw-group.com/product-version/hercules here], to create a test server. Download, install the app and apply the configuration below: |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_9_v1.png|border|class=tlt-border]] |
| | | |
| # Select '''TCP Server''' tab. | | # Select '''TCP Server''' tab. |
Line 100: |
Line 100: |
| In order to setup your router to send Modbus data to server you will need to navigate to '''Services > Modbus > Modbus Data to Server'''. | | In order to setup your router to send Modbus data to server you will need to navigate to '''Services > Modbus > Modbus Data to Server'''. |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_10_v1.png|border|class=tlt-border]] |
| | | |
| # Select '''Protocol''' (In this example HTTP(S) will be used). | | # Select '''Protocol''' (In this example HTTP(S) will be used). |
Line 109: |
Line 109: |
| Then you will be redirected to '''Advanced sender settings'''. | | Then you will be redirected to '''Advanced sender settings'''. |
| | | |
− | [[File:|border|class=tlt-border]] | + | [[File:Networking_rut955_configuration_modbus_serial_11_v1.png|border|class=tlt-border]] |
| | | |
| # Enter '''Name''' (It can be anything you want). | | # Enter '''Name''' (It can be anything you want). |