Line 27: |
Line 27: |
| | configurableio = {{{configurableio}}} | | | configurableio = {{{configurableio}}} |
| | input_volts = {{{input_volts}}} | | | input_volts = {{{input_volts}}} |
− | }}{{#switch: {{{name}}} | + | }}{{#switch: RUT955 |
| | TRB141 =<h3>Input/Output Connector Pinout</h3> | | | TRB141 =<h3>Input/Output Connector Pinout</h3> |
| ---- | | ---- |
− | [[File:Networking_trb141_manual_input_output_input_output_connector_pinout.png]] | + | [[File:Networking_trb141_manual_input_output_input_output_connector_pinout_v2.png]] |
| | | |
| <ul> | | <ul> |
Line 55: |
Line 55: |
| | RUT955|RUT956 =<h3>Input/Output Connector Pinout</h3> | | | RUT955|RUT956 =<h3>Input/Output Connector Pinout</h3> |
| ---- | | ---- |
| + | [[File:Networking_rut955_manual_input_output_input_output_connector_pinout.png]] |
| + | |
| <ul> | | <ul> |
− | <li>Digital input (DIN1): Logic low 0 - 1.2 V; Logic high 1.8 - 3 V</li> | + | <li><b>DI</b><sub>1</sub> and <b>⏚</b><sub>1</sub> - Digital input:</li> |
− | <li>Digital galvanically isolated input (DIN2): 0 - 30 V</li> | + | <ul> |
− | <li>Analog input (voltage mode): 0 – 24 V<span class="asterisk">*</span></li> | + | <li>0-1.2 V is detected as logical "0"</li> |
− | <li>Analog input (current mode): up to 20 mA (commonly used with 4-20 mA standard sensors)</li> | + | <li>1.8-3 V is detected as logical "1"</li> |
− | <li>Digital open collector (OC) output: 30 V, 250 mA</li> | + | </ul> |
− | <li>SPST relay output: 24 V, 4 A</li> | + | <li><b>DI</b><sub>2</sub> and <b>⏚</b><sub>2</sub> - Digital galvanically isolated input:</li> |
| + | <ul> |
| + | <li>0-4 V is detected as logical "0"</li> |
| + | <li>9-30 V is detected as logical "1"</li> |
| + | </ul> |
| + | <li><b>DO</b><sub>1</sub> and <b>⏚</b><sub>3</sub> - Galvanically isolated open collector (OC) output: 30 V, 250 mA</li> |
| + | <li><b>DO</b><sub>2</sub> and <b>⏚</b><sub>3</sub> - OC output: VCC 0-30 VDC.</li> |
| + | <li><b>C & NO</b> - Common and Normally Closed contacts of the internal Latching Relay respectively.<br>Maximum relay ratings: 4 A at 24 VDC, 4 A at 40 VAC.</li> |
| + | <li><b>A</b> and <b>⏚</b><sub>1</sub> - ADC input. Analog voltage range: 0-30 V. The input can be configured for 4-20 mA sensor protocol as current measurement (ACL).<span class="asterisk">*</span></li> |
| + | <li><b>⏚</b><sub>1</sub> - GND for <b>DI</b><sub>1</sub> and <b>A</b>.</li> |
| + | <li><b>⏚</b><sub>2</sub> - GND for <b>DI</b><sub>2</sub>. |
| + | <li><b>⏚</b><sub>3</sub> - GND for <b>DO</b>. |
| </ul> | | </ul> |
| ---- | | ---- |