Changes

Line 27: Line 27:  
| configurableio = {{{configurableio}}}
 
| configurableio = {{{configurableio}}}
 
| input_volts    = {{{input_volts}}}
 
| input_volts    = {{{input_volts}}}
}}{{#switch: {{{name}}}
+
}}{{#switch: RUT955
 
  | TRB141 =<h3>Input/Output Connector Pinout</h3>
 
  | TRB141 =<h3>Input/Output Connector Pinout</h3>
 
----
 
----
[[File:Networking_trb141_manual_input_output_input_output_connector_pinout.png]]
+
[[File:Networking_trb141_manual_input_output_input_output_connector_pinout_v2.png]]
    
<ul>
 
<ul>
Line 55: Line 55:  
| RUT955|RUT956 =<h3>Input/Output Connector Pinout</h3>
 
| RUT955|RUT956 =<h3>Input/Output Connector Pinout</h3>
 
----
 
----
 +
[[File:Networking_rut955_manual_input_output_input_output_connector_pinout.png]]
 +
 
<ul>
 
<ul>
     <li>Digital input (DIN1): Logic low 0 - 1.2 V; Logic high 1.8 - 3 V</li>
+
     <li><b>DI</b><sub>1</sub> and <b>⏚</b><sub>1</sub> - Digital input:</li>
     <li>Digital galvanically isolated input (DIN2): 0 - 30 V</li>
+
        <ul>
     <li>Analog input (voltage mode): 0 – 24 V<span class="asterisk">*</span></li>
+
            <li>0-1.2 V is detected as logical "0"</li>
     <li>Analog input (current mode): up to 20 mA (commonly used with 4-20 mA standard sensors)</li>
+
            <li>1.8-3 V is detected as logical "1"</li>
     <li>Digital open collector (OC) output: 30 V, 250 mA</li>
+
        </ul>
     <li>SPST relay output: 24 V, 4 A</li>
+
     <li><b>DI</b><sub>2</sub>  and <b>⏚</b><sub>2</sub> - Digital galvanically isolated input:</li>
 +
        <ul>
 +
            <li>0-4 V is detected as logical "0"</li>
 +
            <li>9-30 V is detected as logical "1"</li>
 +
        </ul>
 +
    <li><b>DO</b><sub>1</sub> and <b>⏚</b><sub>3</sub> - Galvanically isolated open collector (OC) output: 30 V, 250 mA</li>
 +
    <li><b>DO</b><sub>2</sub> and <b>⏚</b><sub>3</sub> - OC output: VCC 0-30 VDC.</li>   
 +
    <li><b>C & NO</b> - Common and Normally Closed contacts of the internal Latching Relay respectively.<br>Maximum relay ratings: 4 A at 24 VDC, 4 A at 40 VAC.</li>
 +
     <li><b>A</b> and <b>⏚</b><sub>1</sub> - ADC input. Analog voltage range: 0-30 V. The input can be configured for 4-20 mA sensor protocol as current measurement (ACL).<span class="asterisk">*</span></li>
 +
     <li><b>⏚</b><sub>1</sub> - GND for <b>DI</b><sub>1</sub> and <b>A</b>.</li>
 +
     <li><b>⏚</b><sub>2</sub> - GND for <b>DI</b><sub>2</sub>.
 +
     <li><b>⏚</b><sub>3</sub> - GND for <b>DO</b>.
 
</ul>
 
</ul>
 
----
 
----

Navigation menu