Changes

no edit summary
Line 61: Line 61:     
[[File:Networking rut configuration modbus tcp master request v1.png|border|class=tlt-border|1100px]]
 
[[File:Networking rut configuration modbus tcp master request v1.png|border|class=tlt-border|1100px]]
 +
 +
 +
In the '''Register Count / Values''' field we will be written the '''ASCII''' format (human-readable format) and in the '''Data Type''' we will select '''ASCII''' format, so there will be no data conversion that it is why we will be writing in the human-readable format.
 +
 +
 +
The first 10 registers are reserved for the phone number ('''1 register = 4 symbols''') additionally you will require to put in front '+' which is equal to 00 here. If your number (together with 00) does not take 10 registers we will require you to fill out the left registers with 0 values, thats why we use the '''\u0000 symbol''', which means 0 value.
 +
 +
Example Message request:
 +
----
 +
003706xxx1594\u0000\u0000\u0000\u0000\u0000\u0000\u0000test