Difference between revisions of "RUT230 Input/Output"

From Teltonika Networks Wiki
Line 170: Line 170:
 
     <td>Mode</td>
 
     <td>Mode</td>
 
         <td>Fixed {{!}} Interval; Default: '''Fixed'''</td>
 
         <td>Fixed {{!}} Interval; Default: '''Fixed'''</td>
         <td>'''Fixed''' mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM
+
         <td>'''Fixed''' mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM<br>
  
 
'''Interval''' provides you with the possibility to set up an interval after which the same action takes place</td>
 
'''Interval''' provides you with the possibility to set up an interval after which the same action takes place</td>

Revision as of 11:28, 14 December 2018

Main Page > RUT Routers > RUT230 > RUT230 Manual > RUT230 WebUI > RUT230 Services section > RUT230 Input/Output

Summary

This chapter is an overview of the Input/Output function in RUT240 routers.

Status

In the Status page you can review the current state the router’s input and output.


Services inputoutput status rut240.PNG

Custom Labels


If the default Input/Output labels do not suit your needs, you can always configure custom ones. The configuration is simple, just click the Edit button next to the desired Input or Output and you will be redirected to a window such as this:


Services inputoutput status label.PNG


The figure above represents how custom label configuration for Digital Input looks like, but the configuration for the Output is analogous. The changes are purely cosmetic and used for easier management purposes: you can change the Input's/Output's name and the names of its states.

Input

The Input section is used to configure Input.

Input Rules


Input Rules Allow you to set up input parameters and specify what actions should be taken after a specified trigger takes place.


Services inputoutput input configuration.PNG

field name value description
Enable yes | no; Default: yes Toggles the Input rule ON or OFF
Input type Digital; Default: Digital Selects which Input is tied to the rule
Trigger Input open | Input shorted | Both; Default: Input open Specifies the Trigger after which the rule will take effect
Action Send SMS | Change SIM card | Send email | Change profile | Turn on WiFi | Turn off WiFi | Reboot | Activate output | HTTP POST/GET; Default: Send SMS Action to be taken after the Trigger takes place

Send SMS - sends an SMS message to a specified number(s). The message text is custom

Send email - sends an email to the specified address. You will be prompted to enter your email account's authentication information

Change profile - switches the profile in use to the specified profile

Turn on WiFi/Turn off WiFi - turns WiFi ON or OFF

Reboot - reboots the router after a specified amount of time

Activate output - activates specified output

Output

The Output section is used to configure the router's outputs.

Output Configuration


The Output Configuration tab is used to change the default state of outputs.


Services inputoutput output configuration rut240.PNG

field name value description
Open collector output High level | Low level; Default: Low level OC Output state

ON/OFF


The ON/OFF section is used to turn the Output ON or OFF, but it doesn't save the state permanently, meaning that after a reboot the states will revert back to their default values.


Services inputoutput output onoff rut240.PNG

Post/Get Configuration


Services inputoutput output post get.PNG

field name value description
Enable yes | no; Default: no Toggles Output POST/GET function ON or OFF
Username string Default: " " POST/GET service user name
Password string Default: " " POST/GET service user passwor

Periodic Control


Periodic control allows you to set up Output control rules.


Services inputoutput output periodic rut240.PNG

field name value description
Enable yes | no; Default: no Toggles the rule ON or OFF
Output Digital OC output; Default: Digital OC output To which output the rule pertains
Action On | Off; Default: On Periodic action to be taken
Action timeout On | Off; Default: On Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field
Timeout (sec) integer; Default: " " Specifies how long the Action timeout is
Mode Fixed | Interval; Default: Fixed Fixed mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM
Interval provides you with the possibility to set up an interval after which the same action takes place

Scheduler


Scheduler lets you configure a schedule of when the Output is to be enabled or disabled.


Services inputoutput output scheduler rut240.PNG