RUT230 TR-069

From Teltonika Networks Wiki
Revision as of 10:39, 6 October 2021 by Gytispieze (talk | contribs) (Created page with "{{Template: Networking_rutos_manual_tr-069 <!------------------------DEVICE-----------------------> | name = RUT230 | series = RUT2 }}")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > RUT Routers > RUT230 > RUT230 Manual > RUT230 WebUI > RUT230 Services section > RUT230 TR-069

The information in this page is updated in accordance with firmware version RUT2_R_00.07.03.4.

Notice: This device has entered it's EOL (End of Life) cycle. For more information, visit our EOL policy here. Temporarily, some content in this page might not match features found in firmware listed above.

Summary

TR-069 (Technical Report 069) is an application layer protocol designed for management of equipment connected to a remote network.

This chapter of the user manual provides an overview of the UPnP page in RUT230 devices.


TR-069 is additional software that can be installed from the System → Package Manager page.

TR-069 Client Configuration

Networking rutx manual tr-069 client configuration v2.png

Field Value Description
Enable off | on; default: off Turns TR-069 client on or off.
Periodic enable off | on; default: on Turns periodic data transmissions to server on or off.
Accept server request off | on; default: off When enabled the device accepts connection requests from servers.
Sending interval integer [60..9999999]; default: 100 Periodic data transmission frequency (in seconds).
Username string; default: easycwmp Username used for authentication to a TR-069 server.
Password string; default: easycwmp Password used for authentication to a TR-069 server.
URL host | ip; default: http://192.168.1.110:8080/openacs/acs IP address or hostname of a TR-069 server.

Management via TR-069

TR-069 can be used to set or get values from RUT devices. Below is a list of commands used for device management via TR-069.

  • R - read only;
  • RW - read/write;
  • string(64) - 64 bit string;
  • string(256) - 256 bit string;
  • unsignedInt - integer storing only positive values.

Device Information:

  1. DeviceInfo.HardwareVersion - device hardware version (e.g., 0201) R
  2. DeviceInfo.Manufacturer - device manufacturer (e.g., Teltonika) R
  3. DeviceInfo.ManufacturerOUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
  4. DeviceInfo.ProductClass - device model (e.g., RUT230) R
  5. DeviceInfo.ProvisioningCode - provisioning code
  6. DeviceInfo.SerialNumber - device serial number (e.g., 1000111111) R
  7. DeviceInfo.SoftwareVersion - device software version (e.g., RUT2_R_00.0X.XX) R
  8. DeviceInfo.SpecVersion - device special version (e.g., 1.0) R

Device GPS Information:

  1. GPSInfo.Latitude - latitude coordinates of the device (e.g., 0.000000) R
  2. GPSInfo.Longitude - longitude coordinates of the device (e.g., 0.000000) R

Device Mobile Information:

  1. MobileInfo.Modem.1-1.CellID - cell ID
  2. MobileInfo.Modem.1-1.ConnState - connection state (e.g., Connected) R
  3. MobileInfo.Modem.1-1.ConnType - connection type (e.g., LTE) R
  4. MobileInfo.Modem.1-1.EARFCN - absolute radio frequency channel number (e.g., 75) R
  5. MobileInfo.Modem.1-1.ECIO - signal, measured in dB R
  6. MobileInfo.Modem.1-1.ICCID - SIM ICCID R
  7. MobileInfo.Modem.1-1.IMEI - modem IMEI R
  8. MobileInfo.Modem.1-1.IMSI - international mobile subscriber identity R
  9. MobileInfo.Modem.1-1.LAC - location area code R
  10. MobileInfo.Modem.1-1.Manufacture - modem manufacture R
  11. MobileInfo.Modem.1-1.Model - modem model R
  12. MobileInfo.Modem.1-1.NeighbourCells - neighbour cells (e.g., intra,LTE,75,109,-13,-104,-71,0,23,5,12,10,255) R
  13. MobileInfo.Modem.1-1.NetState - operator state (e.g., Registered, home) R
  14. MobileInfo.Modem.1-1.Operator - operator name R
  15. MobileInfo.Modem.1-1.OperatorNum - operator number R
  16. MobileInfo.Modem.1-1.PCI - physical cell identity R
  17. MobileInfo.Modem.1-1.PinState - pin state (e.g., OK) R
  18. MobileInfo.Modem.1-1.RSCP - signal, measured in dBm R
  19. MobileInfo.Modem.1-1.RSRP - signal, measured in dBm R
  20. MobileInfo.Modem.1-1.RSRQ - signal, measured in dB R
  21. MobileInfo.Modem.1-1.RSSI - signal, measured in dBm R
  22. MobileInfo.Modem.1-1.ReceivedThisMonth - data received this month R
  23. MobileInfo.Modem.1-1.ReceivedToday - data received today R
  24. MobileInfo.Modem.1-1.Revision - modem firmware R
  25. MobileInfo.Modem.1-1.SINR - signal, measured in dB R
  26. MobileInfo.Modem.1-1.SentThisMonth - data sent this month R
  27. MobileInfo.Modem.1-1.SentToday - data sent today R
  28. MobileInfo.Modem.1-1.Serial - modem serial number R
  29. MobileInfo.Modem.1-1.SimState - sim state (e.g., Inserted) R
  30. MobileInfo.Modem.1-1.TAC - tracking area code R
  31. MobileInfo.Modem.1-1.Temperature - modem temperature R

Device IP interface information:

  1. IP.Interface.1.Enable - interface enabled/disabled (e.g., true) R
  2. IP.Interface.1.IPv4Address.1.Enable - IPv4 address enabled/disabled (e.g., 1) R
  3. IP.Interface.1.IPv4Address.1.IPAddress - IPv4 address (e.g., 192.168.1.1) R
  4. IP.Interface.1.Name - interface name (e.g., lan) R

Device Management Server information:

  1. ManagementServer.ConnectionRequestPassword - connection request password (e.g., randompassword) R
  2. ManagementServer.ConnectionRequestURL - connection request URL R
  3. ManagementServer.ConnectionRequestUsername - connection request username (e.g., 001E42-RUTX14-0000000000) R
  4. ManagementServer.ParameterKey -
  5. ManagementServer.Password -
  6. ManagementServer.PeriodicInformEnable - enabled/disabled TR-069 client periodic data transmission to TR-069 server (e.g., true) R
  7. ManagementServer.PeriodicInformInterval - periodic data transmission interval (e.g., 300) R
  8. ManagementServer.PeriodicInformTime - periodic information time (e.g., 1/1/1970, 8:09:27 PM) R
  9. ManagementServer.URL - server URL R
  10. ManagementServer.Username - server username R

Device ID information:

  1. DeviceID.ID - device ID (e.g., 001E42-RUTX14-0000000000) R
  2. DeviceID.Manufacturer - device manufacturer (e.g., Teltonika) R
  3. DeviceID.OUI - organizationally unique identifier of the device manufacture (e.g., 001E42) R
  4. DeviceID.ProductClass - product class (e.g., RUTXXX) R
  5. DeviceID.SerialNumber - device serial number R

Events information:

  1. Events.0_BOOTSTRAP - bootstrap time R
  2. Events.1_BOOT - boot time R
  3. Events.Inform - information time R
  4. Events.Registered - events reg time R