Line 10: |
Line 10: |
| | | |
| This manual page provides an overview of the RS232 page in {{{name}}} devices. | | This manual page provides an overview of the RS232 page in {{{name}}} devices. |
− | {{#ifeq:{{{series}}}|TRB14X| | + | {{#ifeq: {{{series}}} | TRB1 | |
| ==General information== | | ==General information== |
| | | |
Line 83: |
Line 83: |
| The <b>RS232 Configuration</b> section is used to set up the main operating parameters and the serial type of the RS232 connector. | | The <b>RS232 Configuration</b> section is used to set up the main operating parameters and the serial type of the RS232 connector. |
| | | |
− | [[File:Networking_rutos_manual_rs232_rs232_configuration.png|border|class=tlt-border]] | + | [[File:Networking_rutos_manual_rs232_rs232_configuration_data_bits_{{{data_bits}}}.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 98: |
Line 98: |
| <tr> | | <tr> |
| <td>Baud rate</td> | | <td>Baud rate</td> |
− | <td>300 | {{#ifeq:{{{series}}}|TRB2XX|600 <nowiki>|</nowiki> |}}1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200{{#ifeq:{{{series}}}|TRB2XX| <nowiki>|</nowiki> 230400 <nowiki>|</nowiki> 460800 <nowiki>|</nowiki> 921600 <nowiki>|</nowiki> 1000000 <nowiki>|</nowiki>|}} 3000000; default: <b>{{#ifeq:{{{series}}}|TRB2XX|300|115200}}</b></td> | + | <td>300 | {{#ifeq:{{{series}}}|TRB2|600 <nowiki>|</nowiki> |}}1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200{{#ifeq:{{{series}}}|TRB2| <nowiki>|</nowiki> 230400 <nowiki>|</nowiki> 460800 <nowiki>|</nowiki> 921600 <nowiki>|</nowiki> 1000000 <nowiki>|</nowiki>|}} 3000000; default: <b>{{#ifeq:{{{series}}}|TRB2|300|115200}}</b></td> |
| <td>Data rate for serial data transmission (in bits per second).</td> | | <td>Data rate for serial data transmission (in bits per second).</td> |
| </tr> | | </tr> |
| <tr> | | <tr> |
| <td>Data bits</td> | | <td>Data bits</td> |
− | <td>{{#ifeq:{{{series}}}|TRB14X|5 <nowiki>|</nowiki> 6 <nowiki>|</nowiki> |}}7 | 8; default: <b>{{#ifeq:{{{series}}}|TRB2XX|7|8}}</b></td> | + | <td>{{#ifeq:{{{series}}}|TRB1|5 <nowiki>|</nowiki> 6 <nowiki>|</nowiki> |}}7 | 8; default: <b>{{{data_bits}}}</b></td> |
| <td>Number of data bits for each character.</td> | | <td>Number of data bits for each character.</td> |
| </tr> | | </tr> |
Line 219: |
Line 219: |
| The <b>Modbus gateway</b> serial type allows redirecting TCP data coming to a specified port to an RTU specified by the Slave ID. The Slave ID can be specified by the user or be obtained directly from the Modbus header. | | The <b>Modbus gateway</b> serial type allows redirecting TCP data coming to a specified port to an RTU specified by the Slave ID. The Slave ID can be specified by the user or be obtained directly from the Modbus header. |
| | | |
− | [[File:Networking_rutos_manual_rs485_rs485_configuration_modbus_gateway.png|border|class=tlt-border]] | + | [[File:Networking_rutos_manual_usb_tools_printer_server_usb_to_serial_modbus_gateway.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |