Changes

no edit summary
Line 1: Line 1:  
<table class="nd-othertables_3">
 
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (12 V)</td>
 +
      <td><b>26</b></td>
 +
      <td><b>0.31</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (24 V)</td>
 +
      <td><b>20</b></td>
 +
      <td><b>0.48</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (44 V)</td>
 +
      <td><b>15</b></td>
 +
      <td><b>0.64</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (50 V)</td>
 +
      <td><b>14</b></td>
 +
      <td><b>0.70</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Idle (57 V)</td>
 +
      <td><b>13</b></td>
 +
      <td><b>0.77</b></td>
 +
    </tr>
 +
</table>
 +
 +
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (12 V)</td>
 +
      <td><b>148</b></td>
 +
      <td><b>1.82</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (24 V)</td>
 +
      <td><b>82</b></td>
 +
      <td><b>1.93</b></td>
 +
    </tr>
 
     <tr>
 
     <tr>
         <th width=250>State</th>
+
        <td>5 LAN devices connected + heavy data traffic (44 V)</td>
      <th width=200>Average power (W)</th>
+
      <td><b>52</b></td>
       <th width=100>Peak power (W)</th>
+
      <td><b>2.31</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (50 V)</td>
 +
      <td><b>48</b></td>
 +
      <td><b>2.40</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>5 LAN devices connected + heavy data traffic (57 V)</td>
 +
      <td><b>44</b></td>
 +
      <td><b>2.50</b></td>
 +
    </tr>
 +
</table>
 +
 
 +
 
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
         <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
       <th width=150>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Idle</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (44 V)</td>
        <td>0.457</td>
+
      <td><b>444</b></td>
        <td>1.311</td>
+
      <td><b>19.54</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>PoE devices connected</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (50 V)</td>
        <td>27.517<span class="asterisk">*</span></td>
+
      <td><b>388</b></td>
        <td>37.448<span class="asterisk">*</span></td>
+
      <td><b>19.40</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Heavy data traffic</td>
+
         <td>4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic (57 V)</td>
        <td>2.033</td>
+
      <td><b>343</b></td>
        <td>8.4</td>
+
      <td><b>19.55</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
   −
<font size="-1"><span class="asterisk">*</span>Capable of up to 102 W; depends on power supply.</font>
+
 
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150>Current (mA)</span></th>
 +
      <th width=150>Power consumption (W)</th>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (44 V)</td>
 +
      <td><b>1789</b></td>
 +
      <td><b>78.72</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (50 V)</td>
 +
      <td><b>2050</b></td>
 +
      <td><b>102.50</b></td>
 +
    </tr>
 +
    <tr>
 +
        <td>4 PoE dummy loads connected (30 W each) (57 V)</td>
 +
      <td><b>2344</b></td>
 +
      <td><b>133.61</b></td>
 +
    </tr>
 +
</table>